Priority switch - Load shedding relay 6,7...39A E 452-5,7 A

E 452-5,7 A 2CDE160010R0901 4016779209502 EAN/GTIN DE 91945327 WEEE

Our best price
£19.02 incl. VAT (£0.00)
£31.08 (-38.8% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Priority switch E 452-5.7 A, rated voltage 400V, rated current 6.7 ... 39A, response current 3.1... more
Priority switch - Load shedding relay 6,7...39A E 452-5,7 A – ABB – 2CDE160010R0901 – 4016779209502: Priority switch E 452-5.7 A, rated voltage 400V, rated current 6.7 ... 39A, response current 3.1 ... 5.3A, max. release delay 20ms, max Contacts as NC contact 1, number of contacts as changeover contact 0, rated current (control contacts) 1A, max. switching voltage (control contacts) 400V, max. switching capacity (control contacts) 230VA, electrical service life (control contacts) 100000 switching cycles, mechanical service life (control contacts) 2000000 switching cycles, max. electrical switching frequency 1800c/h, width in modular widths 1, priority switches are used in installations in which the existing conductor cross-sections or the size of the power supply connection do not allow the simultaneous operation of two powerful consumers (e.g. storage heater and heat exchanger). Priority switches separate the long-term consumer (storage heater) as long as the short-term consumer (heat exchanger) is switched on. The current coil of the priority switch is connected in series with the short-time consumer. When the consumer is switched on, the opener of the priority switch disconnects e.g. B. the contactor of the heating system.
... more
Rated voltage 230V
Max. Waste delay 20 ms
Max. Continuous current 43 A
Number of contacts as opener 1
Rated current (control contacts) 1 A
Max. Switching voltage (control contacts) 400V
Max. Switching capacity (control contacts) 230 VA
Max. Electrical switching frequency 1800 c/h
Voltage AC
Mounting DIN rail
Width in division units 1
Depth 60 mm
IP protection) IP40