Transformer kilowatt-hour meter 1A B24 352-100

B24 352-100 2CMA100183R1000 7392696001830 EAN/GTIN DE 91945327 WEEE

Our best price
£188.38 incl. VAT (£0.00)
£370.46 (-49.15% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Instrument transformer meter RS485 B24 352-100 Electronic meter type, rated current (In) 1A,... more
Transformer kilowatt-hour meter 1A B24 352-100 – ABB – 2CMA100183R1000 – 7392696001830: Instrument transformer meter RS485 B24 352-100 Electronic meter type, rated current (In) 1A, maximum current (Imax) 6A, rated voltage (Un) NL 230 ... 240V, rated voltage (Un) LL 380 ... 415V, frequency 50 ... 60Hz, Accuracy class C, Polart four-wire, measuring transducer design, energy type active and reactive power, suitable for import/delivery, multi-tariff tariff design, external tariff control, backstop, calibrated, Measuring Instruments Directive approval, electrical pulse output, pulse type S0, pulse rate 1 ... 999999imp/kWh (kvarh), display type digital, mounting type REG, width in pitch units 4, design of the Modbus interface, number of digits 7, degree of protection (IP) IP20, degree of protection (NEMA) other, three-phase meter for measuring a three-wire or four-wire three-phase network via a converter -Connection CT (transformer ratio for current configurable) up to a maximum of 6 A. The following values are output via a seven-segment display with up to 7 digits: active energy (class 0.5) and reactive energy ( Class 2) for import and export, power, current, voltage (LL, LN), frequency, cos phi, power factor and apparent power, both per phase and overall. Communication can take place via the integrated RS485 interface (Modbus RTU) or via the infrared interface for connecting a KNX module. The energy meter has 2 permanently configured inputs and outputs. The output can be used either as a pulse output to output active or reactive energy or as an alarm output. Up to 25 alarm values (threshold values with a time delay) can be set here. The inputs are used to control the tariffs or to count external pulses. The resettable intermediate counter enables individual intervals to be measured. In addition, the meter records up to 4 tariffs. The meter is calibrated according to MID and approved according to IEC. The installation width is 4 DIN modules.
... more
Counter type electronic
Rated current (in) 6A
Maximum current (Imax) 6A
Rated voltage (Un) NL 230..240 V
Rated voltage (Un) LL 380..415 V
Frequency 50..60 Hz
Accuracy class C
Polart Four conductors
Execution Transducers
Of energy Active and reactive power
Suitable for Purchase / delivery
Rate design Multi-tariff
Tariff control external
Measurement type load profile no
Backstop yes
Calibrated yes
Admission Measuring Instruments Directive
Pulse output electrical
Pulse type S0
Pulse rate 59,0909 lm/W
Display digital
Mounting REG
Width in division units 4
Width 70 mm
Depth 65 mm
Height 26.5 mm
Execution of the interface other
EDL40 signature no
With lock code no
Number of digits 7
IP protection) IP20
Protection class (NEMA) other