Graphic Fixed installation safety tester BENNING IT 105

BENNING IT 105 044105 4014651441057 EAN/GTIN DE 83723692 WEEE

Our best price
£649.81 incl. VAT (£0.00)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Installation tester with graphic display BENNING IT 105 Graphic display, insulation resistance... more
Graphic Fixed installation safety tester BENNING IT 105 – Benning – 044105 – 4014651441057: Installation tester with graphic display BENNING IT 105 Graphic display, insulation resistance measurement, resistances of insulating floors and walls, low-ohm measurement, loop resistance/impedance measurement, loop measurement without RCD/FI tripping, internal network resistance measurement, determination of short-circuit current/overcurrent protective devices, RCD/FI test, waveform for RCD/FI testing for residual current circuit breakers type A, F, RCD/FI testing with increasing residual current, RCD/FI analysis function, rotating field test, Benning IT 105. Multifunctional installation tester. Multifunctional installation tester for testing electrical systems in accordance with DIN VDE 0100-600, IEC 60364-6 and DIN VDE 0105-100, EN 50110. Graphic display. Backlit graphic display. Measurements: Insulation resistance measurement yes. Insulation resistance 0.20 MOhm - 199 MOhm. Rated test voltage 250 V. Rated test voltage 500 V. Rated test voltage 1000 V. Resistances of insulating floors and walls yes. Yes, low-impedance measurement. Low-ohm resistance 0.15 ohms - 199 ohms, test current 200 mA and continuity. Loop resistance/impedance measurement yes. Loop measurement without RCD/FI tripping yes. Line impedance 0.20 Ohm - 1999 Ohm LN/ L, with calculation of the short-circuit current. Loop impedance 0.20 Ohm - 1999 Ohm L-PE, without RCD/FI tripping and short-circuit current. Internal network resistance measurement yes. Determination of short-circuit current/overcurrent protection devices yes. RCD/FI test yes. Curve shape for RCD/FI test for type A, F, AC residual current circuit breakers. Test current sinusoidal (AC) and pulsating direct current (A), standard and delayed (S). RCD/FI test with increasing fault current yes. RCD/FI analysis function yes. Testing of RCDs standard and delayed S, type AC, A, F with AUTO test, trip time and trip current with ramp test. rotary field test yes. Voltage measuring range AC/DC 1 V - 440 V. Frequency measuring range 45 Hz - 65 Hz. Special features: Extra large graphic display 95 x 55 mm with background lighting. Test tip with TEST button to start the measurement process. AUTO start function for low-impedance loop and line impedance measurement. LOCK function Continuous measurement of the insulation resistance, zero adjustment of the measuring lines up to 10 ohms for RPE measurement. Including robust hard case, test probe with TEST button, test probe/crocodile clip set, test line with safety plug, shoulder strap, 6 x 1.5 V mignon batteries, calibration certificate, fuse 1.6 A (10194027)
... more
Display graphic
Limit indicator no
Insulation resistance measurement yes
Überspannungsableiterprüfung no
Low- yes
Low resistance measurement with ramp function no
Earth measurement no
Selective grounding measurement no
Earth Ground no
Specific grounding measurement no
Loop resistance / impedance measurement yes
Loop measurement without RCD / FI tripping yes
Mains internal resistance measurement yes
RCD / FI test yes
RCD / FI test with increasing fault current yes
RCD / FI analysis function yes
PRCD type S, type K test no
Checking IMDs and RCMs no
Measuring leakage currents with adapter no
Phase sequence test yes
Structured measured value memory no
Measurement memory no
Interface no
Printer port no
Integrated printer no
Remote control of the tester no