Isolating spark gap for hazardous area zone 2 - Spark gap for lighting protection EXFS L100

EXFS L100 923060 4013364038899 EAN/GTIN DE 11890845 WEEE

Our best price
£136.17 incl. VAT (£0.00)
£257.90 (-47.2% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Isolating spark gap f.Ex area zone 2 EXFS L100, lightning impulse current (10/350 µs)=50 kA,... more
Isolating spark gap for hazardous area zone 2 - Spark gap for lighting protection EXFS L100 – Dehn – 923060 – 4013364038899: Isolating spark gap f.Ex area zone 2 EXFS L100, lightning impulse current (10/350 µs)=50 kA, rated response impulse voltage=2.5 kV, rated AC withstand voltage=300 V, connection=flange, suitable for connection=other, material of the Connections=stainless steel (V2A), surface=galvanized/electrolytically zinc-plated, explosion-tested version=yes, degree of protection (IP)=IP54, isolating spark gaps for the Ex area for indirect connection/grounding of operationally separated system parts in the event of lightning. For safe use in explosion protection zone 2 (gases). ATEX-certified isolating spark gap for lightning protection equipotential bonding according to DIN EN 62305 / VDE 0185 in a proven design with flexible conductor connection.
... more
Lightning impulse current (10/350 µs) 50 kA
Measuring impulse sparkover voltage 2.5 kV
Measuring power frequency withstand voltage 300V
Connection Flange
Suitable for connection other
Material of the connection Stainless steel (V2A)
Explosion-tested version yes
IP protection) IP54