Surge arrester DEHNsafe - Surge protection device 230V 2-pole DSA 230 LA

DSA 230 LA 924370 4013364081321 EAN/GTIN DE 11890845 WEEE

Our best price
£48.39 incl. VAT (£0.00)
£122.54 (-60.51% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
ÜS arrester DEHNsafe DSA 230 LA Type of mounting on-wall/flush-mounted, rated voltage AC 230V,... more
Surge arrester DEHNsafe - Surge protection device 230V 2-pole DSA 230 LA – Dehn – 924370 – 4013364081321: ÜS arrester DEHNsafe DSA 230 LA Type of mounting on-wall/flush-mounted, rated voltage AC 230V, maximum continuous voltage AC 255V, rated load current 16A, rated discharge current (8/20) (LN) 3kA, total discharge current (8/20) (L+N-PE) 5kA, Protection level LN 1.25kV, protection level L-PE/N-PE 1.5kV, number of poles 2, acoustic and optical signaling on the device, max. conductor cross-section solid (solid/stranded) 2.5mm², max. conductor cross-section flexible (finely stranded) 2 .5mm², test class type 3, degree of protection (IP) IP20, surge arrester DEHNsafe 230 LA, type 3 according to EN 61643-11 with monitoring device and disconnector. Increased security through mistake-proof Y protection circuit. To protect electronic devices from overvoltages. For installation in electrical installation systems, e.g. B. Cable ducts and accessory mounting boxes. For use in the lightning protection zone concept at the interfaces 1 - 2 and higher.
... more
Rated voltage AC 230V
Highest continuous voltage AC 255V
Nominal load current 16 A
Nominal discharge current (8/20) (LN) 3 kA
Total discharge current (8/20) (L + N-PE) 5 kA
Protection level LN 1.25 kV
Protection level L-PE / N-PE 1.5 kV
Number of poles 2
Mounting Wall-mounted/flush
With telecommunication contact no
Signaling on the device acoustically and visually
Test class type 3 yes
With noise filter no
IP protection) IP20