FI/LS combination - Earth leakage circuit breaker DRCBO3 B16/0,03/1N-A

DRCBO3 B16/0,03/1N-A 09932104 4014712220621 EAN/GTIN DE 85624250 WEEE

Our best price
£24.64 incl. VAT (£0.00)
£152.52 (-83.84% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Earth leakage circuit breaker B16/0,03A Number of poles (total) 2, Number of protected poles 1,... more
FI/LS combination - Earth leakage circuit breaker DRCBO3 B16/0,03/1N-A – Doepke – 09932104 – 4014712220621: Earth leakage circuit breaker B16/0,03A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated insulation voltage Ui 440V, Rated impulse withstand voltage Uimp 4kV, Rated current 16A, Rated fault current 0,03A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity Icn acc. EN 61009-1 10kA, Disconnection characteristic Undelayed, Surge current capacity 0,25kA, Voltage type AC, Frequency 50 Hz, Release characteristic B, Over voltage category 3, Pollution degree 2, Ambient temperature during operating -25 ... 40°C, Width in number of modular spacings 2, Built-in depth 68mm, Degree of protection (IP) IP20, Connectable conductor cross section solid-core 1 ... 25mm², Connectable conductor cross section multi-wired 1 ... 25mm²
... more
Number of poles (total) 2
Number of secured poles 1
Rated voltage 230V
Rated insulation voltage Ui 440V
Rated impulse withstand voltage Uimp 4 kV
Rated current 16 A
Rated fault current 0.03 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 10 kA
turn-off characteristic instantaneously
Surge current resistance 0.25 kA
Voltage AC
Frequency 50 Hz
Release characteristic B
Coupling neutral conductor yes
With locking device yes
Overvoltage category 3
Pollution degree 2
Width in division units 2
Depth 68 mm
Flush mounting no
False triggering protection no
IP protection) IP20

Rate item