RCD combination/RCBO - Earth leakage circuit breaker DRCBO3 B16/0,3/1N-A

Doepke - DRCBO3 B16/0,3/1N-A - RCD combination/RCBO - Earth leakage circuit breaker DRCBO3 B16/0,3/1N-A
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DRCBO3 B16/0,3/1N-A 09932114 4014712220669 EAN/GTIN DE 85624250 WEEE

Our best price
£43.05 incl. VAT (£0.00)
£152.73 (-71.81% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI/LS combination/RCBO DRCBO3 B16/0.3/1N-A number of poles (total) 2, number of fused poles 1,... more
RCD combination/RCBO - Earth leakage circuit breaker DRCBO3 B16/0,3/1N-A – Doepke – 09932114 – 4014712220669: FI/LS combination/RCBO DRCBO3 B16/0.3/1N-A number of poles (total) 2, number of fused poles 1, rated voltage 230V, rated insulation voltage Ui 440V, rated impulse withstand voltage Uimp 4kV, rated current 16A, rated residual current 0.3A, residual current Type A, energy limitation class 3, rated breaking capacity according to EN 61009 10kA, rated breaking capacity according to IEC 60947-2 10kA, rated short-circuit breaking capacity Icn according to EN 61009-1 10kA, instantaneous switch-off characteristic, surge current strength 0.25kA, type of voltage AC, frequency 50 Hz, tripping characteristic B, overvoltage category 3, Pollution degree 2, ambient temperature during operation -25 ... 40°C, width in pitch units 2, installation depth 68mm, degree of protection (IP) IP20, connectable conductor cross-section solid 1 ... 25mm², connectable conductor cross-section stranded 1 ... 25mm², combine RCBO Residual current circuit breaker and miniature circuit breaker in one device (FI/LS combination). They protect people from fault currents and systems from short circuits and overloads. The switches of the DRCBO 3 series work independently of the mains voltage and are characterized by a high rated switching capacity. Separate displays enable a quick overview of the current operating status. DRCBO 3 can be easily installed and removed. Type A switches are pulse and AC sensitive. This function is independent of the mains voltage. Switches with tripping characteristic B are the standard protection for light and socket circuits. Standard switches are designed for circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz. Properties: tripping independent of auxiliary voltage, sensitive to AC and pulsating DC residual currents (type A) small size for all rated currents, high short-circuit strength, green-red contact position indicator, residual current tripping indicator, clamping yoke terminals with protection from behind and wide terminal cross-section range for rail and cable wiring on both connection sides, neutral conductor on the right, tristable latching slide for easy installation and removal, type of installation: quick fastening on DIN rail, any installation position, any supply, areas of application: protection of circuits in residential and commercial buildings as well as industrial plants with TN-S and TN-CS networks. In IT networks, RCBOs can be provided to switch off in the event of a second earth fault. Use in systems with TN-C networks and to protect circuits is excluded. in which power electronics equipment can cause smooth DC fault currents or fault currents with frequencies not equal to 50/60 Hz.
... more
Number of poles (total) 2
Number of secured poles 1
Rated voltage 230V
Rated insulation voltage Ui 440V
Rated impulse withstand voltage Uimp 4 kV
Rated current 16 A
Rated fault current 0,29999999 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 10 kA
turn-off characteristic instantaneously
Surge current resistance 0.25 kA
Voltage AC
Frequency 50 Hz
Release characteristic B
Coupling neutral conductor yes
With locking device yes
Overvoltage category 3
Pollution degree 2
Width in division units 2
Depth 68 mm
Flush mounting no
False triggering protection no
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "RCD combination/RCBO - Earth leakage circuit breaker DRCBO3 B16/0,3/1N-A"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.