BA9043 3AC 230/400V 0039676 4030641396763 EAN/GTIN DE 92994522 WEEE

Our best price
£157.58 incl. VAT (£0.00)
£238.76 (-34% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Undervoltage relay 50/60HZ BA9043 3AC 230/400V, design of the electrical connection=screw... more
Undervoltage relay 50/60HZ - Voltage monitoring relay 0...480V AC BA9043 3AC 230/400V – Dold – 0039676 – 4030641396763: Undervoltage relay 50/60HZ BA9043 3AC 230/400V, design of the electrical connection=screw connection, with removable terminals=no, 1-phase undervoltage possible=no, 3-phase undervoltage possible=yes, 1-phase overvoltage possible=no, 3-phase overvoltage possible=no, 1-phase window possible=no, 3-phase window possible=no, includes DC undervoltage function=no, includes DC overvoltage function=no, includes DC window function=no , voltage measuring range 1=0..480 V, type of voltage of the measuring range=AC, rated control supply voltage Us at AC 50 Hz=230..400 V, rated control supply voltage Us at AC 60 Hz=230..400 V, response value voltage=340..420 V , number of contacts as changeover contact=2, width=45 mm, height=73 mm, depth=132 mm, voltage monitoring relay with arithmetic mean value measurement, according to IEC/EN 60 255, DIN VDE 0435-303, for networks with or without neutral conductor, quiescent current principle (Output relay not activated in case of error), LED-A Indicators for operational readiness and contact position, insensitive to harmonics, suitable for networks from 50 ... 400 Hz
... more
With removable clamps no
1-phase undervoltage possible no
3-phase undervoltage possible yes
1-phase overvoltage possible no
3-phase overvoltage possible no
1-phase window possible no
3-phase window possible no
Contains function DC voltage window no
Voltage measuring range 1 0..480 V
Voltage type of the measuring range AC
Pickup voltage 340..420 V
Number of contacts as changer 2
Width 45 mm
Height 73 mm
Depth 132 mm