AFD unit, 2-pole, B16A, 30mA - Earth leakage circuit breaker with AFDD-16/2/B/003-A

AFDD-16/2/B/003-A 187204 4015081822539 EAN/GTIN DE 92318050 WEEE

Our best price
£79.76 incl. VAT (£0.00)
£184.32 (-56.73% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
AFD unit 2-pole, B16A, 30mA AFDD-16/2/B/003-A number of poles 2, rated voltage 230V, rated... more
AFD unit, 2-pole, B16A, 30mA - Earth leakage circuit breaker with AFDD-16/2/B/003-A – Eaton – 187204 – 4015081822539: AFD unit 2-pole, B16A, 30mA AFDD-16/2/B/003-A number of poles 2, rated voltage 230V, rated current 16A, rated residual current 0.03A, residual current type A, energy limitation class 3, rated breaking capacity according to EN 61009 10kA, rated breaking capacity according to IEC 60947- 2 0kA, frequency 50Hz, tripping characteristic B, overvoltage category 3, degree of pollution 2, width in pitch units 3, installation depth 67mm, additional devices installed at the factory AFD unit, rated switching current additional device 0A, rated voltage additional device 230V, control voltage type additional device AC, protection class (IP) IP20, high-quality fire protection switch (fault arcing protective device) with residual current circuit breaker/miniature circuit breaker combination, independent of mains voltage, contact position indicator red - green, terminal plug-in protection, tristable locking slide - enables expansion from an existing busbar system, extensive range of accessories can be retrofitted, g Large selection of rated residual currents, rated currents up to 40 A, tripping characteristics B, C, D, rated switching capacity 10 kA, suitable for outdoor use (site and outdoor distribution boards) down to -25 °C
... more
Number of poles 2
Rated voltage 230V
Rated current 16 A
Rated fault current 0.03 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 10 kA
Rated switch-off capacity according to IEC 60947-2 0 kA
Frequency 50 Hz
Release characteristic B
Coupling neutral conductor no
Overvoltage category 3
Pollution degree 2
Width in division units 3
Depth 67 mm
Rated switching current additional device 0A
Rated voltage additional device 230V
Control voltage type option AC
IP protection) IP20

Rate item