KNX IP Router PoE N000402

N000402 DE 31640810 WEEE

Our best price
£204.68 incl. VAT (£0.00)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Note: The Power over Ethernet supply is standardized acc. to Standard PoE (IEEE 802.3af) and... more
KNX IP Router PoE N000402 – EIBMARKT: Note: The Power over Ethernet supply is standardized acc. to Standard PoE (IEEE 802.3af) and integrated via RJ45. We can recommend a PoE Ethernet Switch from Netgear, e.g. FS108P. The device disposes of 8 ports, four of which are equipped with Power over Ethernet (IEEE802.3af, 48 VDC). The IP Router, for example, can be connected to one of these four ports. As an alternative, power supply can be provided by means of screw connecting terminals at the upper side using a separate power supply unit (12-24V DC) or transformer (12-24V AC). Parallel power must be avoided! Caution when using managed Switches (Cisco or similar): With some Switches there can problems with the standard settings and the IP devices are not recognized. In this case make the following adjustment at the Switch: Full-Duplex-Mode Digit rate: 10 Megabit/s A blinking Ethernet LED at the IP Router or IP Interface indicates an existing link i.e. the digit rate and the mode have been set correctly. The KNX IP Router is capable of Routing and Tunnelling at the same time, i.e. ETS programming (Tunnelling) and coupler function (Routing) are possible in parallel. KNXnet/IP Tunnelling allows only one connection by means of the KNX IP Router interface function to the bus. With Routing several devices can access the bus simultaneously. Routing is preferably used when the KNX IP Router is applied as line or area coupler. However, it can, for example, also be used for the connection of a visualization application. Applications: For ETS-programming a KNX IP interface that supports only the tunnelling protocol is sufficient (KNX IP interface instead of KNX IP Router). However, the ETS also supports programming by means of the routing protocol. If you want to connect visualizations, it must be verified which protocol the respective software supports. So, the current Gira HomeServer supports nothing but the routing protocol. For simultaneous access of several applications the routing protocol is required (KNX IP Router), while one application can make use of the tunnelling protocol. Remote internet access is always achieved via tunnelling protocol. KNX/EIB IP Router IP-Router / Interface between LAN and EIB/KNX bus Application area The KNXnet/IP router allows forwarding of telegrams between different lines (as EIB KNX area/line coupler) through a LAN (IP) as a fast backbone. In addition this device is suited to connect a PC to the KNX/EIB network e.g. for ETS programming. The IP address can be obtained by a DHCP server or by manual configuration (ETS) respectively. This device works according to the KNXnet/IP specification using the core, the device management, the tunnelling and the routing part. The KNX IP Router has a filter table and is able to buffer up to 150 telegrams. Technical data   Electrical safety   - Protection (EN 60529): IP 20   - Safety extra low voltage SELV DC 24 V   EMC requirements   - Complies with EN 61000-6-2, EN 61000-6-3 and EN 50090-2-2   Environmental requirements   - Ambient temp. operating: - 5 ... + 45 °C   - Ambient temp. Non-op.: - 25 ... + 70 °C   - Rel. humidity (non-condensing): 5 % … 93 %   Certification   - EIB/KNX   CE norm   - Complies with the EMC regulations (residential and functional buildings) and     low voltage directive   Physical specifications   - Housing: Plastic   - DIN rail mounted device, width: 36 mm   - Weight: approx. 100 g   - Fire load: approx. 1000 kJ   Operating controls   - Learning key for EIB/KNX   Indicators   - Learning-LED (red)   - Signal-LED (green) for EIB/KNX   - Signal-LED (green) for LAN   Ethernet   - 10BaseT (10Mbit/s)   - Supported internet protocols ARP, ICMP, IGMP, UDP/IP and DHCP   Power supply   - External supply 12-24V   - Alternative: Power-over-Ethernet   - Power consumption: < 800 mW   Connectors   - EIB/KNX connection terminal   - LAN RJ-45 socket   - Screw connector for power supply Manufacturer: EIBMARKT GmbH Item number: N000402 photographed by EIB3D.COM
... more

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "KNX IP Router PoE N000402"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.