Wireless alternating current meter transmitter module - Energy meter for bus system FWZ14-65A

FWZ14-65A 30014050 4010312501511 EAN/GTIN DE 30298319 WEEE

Our best price
£51.30 incl. VAT (£0.00)
£73.01 (-29.74% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Wireless alternating current meter transmission module FWZ14-65A Bus system radio bus, other bus... more
Wireless alternating current meter transmitter module - Energy meter for bus system FWZ14-65A – Eltako – 30014050 – 4010312501511: Wireless alternating current meter transmission module FWZ14-65A Bus system radio bus, other bus systems without, energy meter design, connection type direct, S0 pulse interface without, accuracy class 1, RS485 bus radio alternating current meter, maximum current 65A, stand-by loss only 0.5 watts . Modular installation device for mounting on mounting rail DIN-EN 60715 TH35. 1 pitch unit = 18mm wide, 58mm deep. Accuracy class B (1%). With RS485 interface. Connection to the Eltako RS485 bus. Bus cross-wiring and power supply with jumper. The meter reading, the instantaneous output and the serial number are transferred to the bus - eg for transfer to an external computer, the GFVS 4.0 software or GFVS-Energy - and also sent to the wireless network via the FAM14. To do this, it is necessary for the FAM14 wireless antenna module to assign a device address, as described in the operating instructions. Display also with FEA65D. The alternating current meter measures the active energy based on the current flowing between the input and output. The self-consumption of only a maximum of 0.5 watts is not measured. Like all meters without an MID declaration of conformity in Europe, not approved for monetary electricity billing. An outer conductor with a current of up to 65A can be connected. The starting current is 4OmA. During operation, the rotary switch must be set to AUTO. The power consumption is displayed with a flashing LED. If the L input and L output were swapped when connecting, an HT/NT switchover telegram is sent every 20 seconds to indicate the connection error. If the load is expected to be more than 50%, a ventilation distance of 1/2 module to devices installed next to it must be maintained. For this purpose, the scope of delivery includes 2 spacers DS14 and, in addition to the short jumper, two further long jumpers.
... more
Bus system KNX no
Bus system KNX radio no
Bus system radio bus yes
Bus system LON no
Bus system Powernet no
Other bus systems without
Radio bidirectional no
Execution Energy counter
Connection directly
Approval according to PTB no
S0 pulse interface without
Tariff switching no
Accuracy class 1

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Wireless alternating current meter transmitter module - Energy meter for bus system FWZ14-65A"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.