Binary input 6-fold KNX 10-230V AC/DC 212600

212600 4010337018834 EAN/GTIN DE 59229780 WEEE

Our best price
£116.47 incl. VAT (£0.00)
£210.34 (-44.63% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Binary input 6f. KNX 10-230V AC/DC 212600 bus system KNX, other bus systems without, mounting... more
Binary input 6-fold KNX 10-230V AC/DC 212600 – Gira – 4010337018834: Binary input 6f. KNX 10-230V AC/DC 212600 bus system KNX, other bus systems without, mounting type REG, width in division units 2, with bus coupling, with LED display, number of inputs 6, input voltage 10 ... 230V, type of input voltage AC/DC, Protection class (IP) IP20, KNX binary input 6-fold 10 - 230 V AC DC REG plus REG binary inputs for connecting contacts. The switching processes of contacts (e.g. monitors or buttons) are converted into KNX telegrams. The inputs can be assigned to different functions or blocked independently of one another. Signal display possible via yellow status LED. Features: Each input has the full range of functions. All channel-oriented functions can be parameterized separately for each input. Actively sending telegrams from the inputs can be globally delayed after bus voltage return or after an ETS programming process. Debounce time and telegram rate limitation can be configured. Free assignment of the functions switching, dimming, blinds, value transmitters and pulse counters to the inputs. Blocking object for blocking individual inputs (polarity of the blocking object adjustable) for the functions switching, dimming, blinds and value transmitter. Behavior when bus voltage returns can be parameterized separately for each input. Switching function: two independent switching objects available for each input (switching commands can be parameterized individually), commands can be set independently for rising and falling edges (ON, OFF, TOGGLE, no reaction), independent cyclic sending of the switching objects depending on the edge or depending on the object value selectable. Dimming function: Single-surface and dual-surface operation, time between dimming and switching and dimming step width adjustable, telegram repetition and stop telegram sending possible. Blind function: command can be set on a rising edge (no function, UP, DOWN, TOGGLE), operating concept can be parameterized (Step - Move - Step or Move - Step), time between short and long-term operation can be set (only with Step - Move - Step), Slat adjustment time adjustable. Value transmitter function: Edge (button as make contact, push button as break contact, switch) and value at edge can be parameterized, value adjustment for button via long key press for value transmitter possible, light scene extension with storage function also saving the scene without prior retrieval possible. Pulse counter function: counting interval adjustable, edge (counting on rising edge, counting on falling edge, counting on rising and falling edge) can be parameterized, number of required pulses at the input can be parameterized, number of required counting pulses for a counter change can be parameterized, each input contains a main counter and an intermediate counter, main counter and intermediate counter can work separately as up or down counters, start and end values of the counters can be specified via parameters or communication object, query counter reading via KNX or automatically, behavior after the counter has expired can be parameterized, reset pulse counter via KNX ( counter reset). The binary input has six independent inputs to which electrical signals in the voltage range from 10 to 230 V are connected. Inputs 1 to 3 and inputs 4 to 6 each have a common reference potential. Different external conductors can therefore be connected per input group, e.g. E.g.: E1-E3 = L1 and E4-E6 = L2. Evaluation of direct voltage signals (DC) or alternating voltage signals (AC).
... more
Bus system KNX yes
Bus system KNX radio no
Bus system radio bus no
Bus system LON no
Bus system Powernet no
Other bus systems without
Radio bidirectional no
Mounting REG
Width in division units 2
With bus coupling yes
Bus module removable no
With LED display yes
Number of inputs 6
Input voltage 10..230 V
Type of input voltage AC/DC
External query voltage necessary no
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Binary input 6-fold KNX 10-230V AC/DC 212600"
Write a review
Evaluations will be activated after verification.