Radio control center - Central fire alarm system 8 groups RFZ050D

Hager - RFZ050D - Radio control center - Central fire alarm system 8 groups RFZ050D
Photo source: fig. possibly similar
Photo source: fig. possibly similar
RFZ050D 3599430039072 EAN/GTIN DE 23692311 WEEE

Our best price
£963.04 incl. VAT (£0.00)
£1,469.40 (-34.46% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
RFZ050D radio control center Type of installation surface-mounted, radio connection, external... more
Radio control center - Central fire alarm system 8 groups RFZ050D – Hager – 3599430039072: RFZ050D radio control center Type of installation surface-mounted, radio connection, external interface, number of alarm groups 8, height 325mm, width 220mm, depth 88mm, number of outputs for acoustic signaling devices 0, number of outputs for optical signaling devices 0, number of detector addresses 30, emergency power supply integrated, with power pack, operating voltage 230V, current consumption 50mA, BEKA center for 50 wireless detectors, white. Bidirectional radio fire detection system for preventive fire protection in the construction and operation of day-care centers for children, in small homes, accommodation facilities, hotels with more than 12 beds up to 60 beds for which no BMZ is required, as well as for residential facilities for seniors, the disabled or other special types of housing . The bidirectional radio transmission is transmitted using two separate radio bands with frequency interference changes in the 434 MHz range with 20 frequencies and in the 868 MHz range with 4 frequencies. A maximum of 64 automatic or manual devices can be controlled and evaluated in the 8 detection areas, which are integrated with automatic sensor head detection and push-button teach-in procedures (max. 64 devices: 50 detectors, 14 wireless indoor sirens or 10 repeaters). The control panel has the connection option for alarm, fault, collective alarm reset with 3 switching inputs, day/night operation and has 4 relay and open collector switching outputs each for the external control of other display devices. The control panel checks the transmission path of the integrated detectors and components bidirectionally within 300 seconds and thus ensures a close-meshed transmission path check. On the central display, status/fault or alarm messages are signaled in plain text with location/time information in combination with the 3-color display as an optical and additional acoustic signal or via the optional GSM module RFW066D for SMS or e-mail to 8 forwarded to defined recipients. The last 1000 events can be viewed chronologically. During commissioning, the configuration is carried out manually on the central display or text entries and other settings, as well as archiving via the USB or RS232 interface can be uploaded or downloaded to the central display using the configuration tool, and after the initial installation has been completed, an automatic overall check of the entire system is carried out and transmitted via USB interface, SD card or optionally with the GSM module by e-mail in the form of a handover/commissioning protocol. With the optional GSM module, after confirmation by a trained person, the control center can forward a status report on the degree of soiling, battery and system status of the individual integrated components by e-mail to a defined recipient at the set maintenance request interval. In the maintenance mode, the results of the maintenance can be transmitted via USB interface, SD card or optionally by e-mail and saved separately and handed over as a maintenance log. Customer level access optionally via PIN code for displaying the day/night function or for temporarily deactivating message areas, as well as for basic customer level settings, resetting fault and alarm messages or optionally for forwarding the maintenance request by e-mail or SMS. Installer level access is via a PIN code, and the main settings of the system can only be configured or changed by the installer. Day/night settings, code changes and other important configuration or setup settings can be made at the installer level. Note: The RFA400D backup battery is not included in the scope of delivery. Approval: DIN EN 54-2, DIN EN 54-4, DIN EN 54-25.
... more
Mounting Construction
Busable no
Radio connection yes
External interface yes
Number of zones 8th
Height 325 mm
Width 220 mm
Depth 88 mm
Number of sensor addresses 30
Integrated emergency power supply yes
With power supply yes
Integrated dialer no
Operating voltage 230V
Current consumption 50mA
Addressable no