Residual current circuit breaker 4p 10kA 63A 500mA A CGA663D

Hager - CGA663D - Residual current circuit breaker 4p 10kA 63A 500mA A CGA663D
Photo source: fig. possibly similar
Photo source: fig. possibly similar
CGA663D 3250611620891 EAN/GTIN DE 23692311 WEEE

£91.33 incl. VAT (£0.00)
£170.46 (-46.42% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Residual current circuit breaker 4p 10kA 63A 500mA A CGA663D number of poles 4, rated voltage... more
Residual current circuit breaker 4p 10kA 63A 500mA A CGA663D – Hager – 3250611620891: Residual current circuit breaker 4p 10kA 63A 500mA A CGA663D number of poles 4, rated voltage 400V, rated current 63A, rated residual current 500mA, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, mounting type DIN rail, residual current type A, short-circuit strength (Icw) 10kA, surge current strength 3kA, frequency 50/60 Hz, additional equipment possible, with locking device, degree of protection (IP) IP20, width in modular widths 4, installation depth 70mm, ambient temperature during operation -25 ... 70°C, degree of pollution 2, connectable conductor cross-section stranded 1 ... 16mm², connectable conductor cross-section solid 1 ... 25mm², residual current circuit breaker 4 pole 10kA 63A 500mA type A. Residual current circuit breaker (FI) according to DIN EN 61008-2-1, VDE 0664 part 10 + 11, protection against accidental contact IP2x according to DIN VDE 0106 part 100. Suitable for retrofitting of additional equipment (assembly without tools). Wire push-in protection terminals, bottom bi-connect terminals, external blue test button. All products with VDE mark. Labeling option directly on the device.
... more
Number of poles 4
Rated voltage 400V
Rated current 63 A
Rated fault current 0.5 A
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
Mounting DIN rail
Fault current type A
Selective type no
Short time delayed type no
Short-circuit strength (Icw) 10 kA
Surge current resistance 3 kA
Voltage AC
With locking device yes
Frequency 50/60 Hz
Additional equipment possible yes
IP protection) IP20
Width in division units 4
Depth 70 mm
Pollution degree 2
Explosion protection no

Rate item