Silencer box conn. 125 or 160 - Sound-barrier for ventilation 35dB SB 12/16

SB 12/16 0059.0995 4012799599951 EAN/GTIN DE 78107228 WEEE

Our best price
£136.55 incl. VAT (£0.00)
£161.85 (-15.63% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Silencer box conn. 125 or 160 SB 12/16, nominal width of duct=435 mm, nominal height of duct=365... more
Silencer box conn. 125 or 160 - Sound-barrier for ventilation 35dB SB 12/16 – Maico – 0059.0995 – 4012799599951: Silencer box conn. 125 or 160 SB 12/16, nominal width of duct=435 mm, nominal height of duct=365 mm, silencer box for ventilation systems. Connection of spiral duct DN 125 with connector SVR 125. Connection of spiral duct DN 160 directly to EPP socket. sealing on site. Made of sound-insulating polypropylene (EPP) with hygienic fleece lamination. With sound-absorbing packing made of mineral-fibre-free melamine resin foam. Two inspection openings. With pre-drilled holes for mounting with threaded rods. Article: SB 12/16, material: plastic EPP, weight: 1.74 kg, width: 435 mm, height: 365 mm, depth: 220 mm, insertion loss at 63 Hz: 2 dB, insertion loss at 125 Hz: 8 dB, Insertion loss at 250 Hz: 12 dB, Insertion loss at 500 Hz: 20 dB, Insertion loss at 1 kHz: 38 dB, Insertion loss at 2 kHz: 47 dB, Insertion loss at 4 kHz: 40 dB, Insertion loss at 8 kHz: 35 dB, Suitable for Box fan: no, Suitable for roof fans: no, Suitable for duct fans: no, Suitable for heat recovery systems: yes, Suitable for wall-mounted fans: no, Suitable for built-in wall fans: no, Suitable for residential building fans: yes, Suitable for centrifugal fans: no, Suitable for circulation fans: no
... more
Suitable for roof ventilators no
Suitable for wall-mounted fans no
Suitable for box fans no
Suitable for circulation fans no
Suitable for tubular fans no
Suitable for centrifugal fans no
Suitable for wall-recessed fans no
Suitable for home ventilators yes
Suitable for heat recovery systems yes