Starter 2.2k - Direct starter combination 2,2kW LG7K06M710

LG7K06M710 3389110658460 EAN/GTIN DE 33842582 WEEE

Our best price
£141.32 incl. VAT (£0.00)
£250.78 (-43.65% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Starter 2.2k LG7K06M710 Type of motor starter Direct starter, with short-circuit release, rated... more
Starter 2.2k - Direct starter combination 2,2kW LG7K06M710 – Schneider Electric – 3389110658460: Starter 2.2k LG7K06M710 Type of motor starter Direct starter, with short-circuit release, rated control supply voltage Us at AC 50 Hz 220 ... 230V, rated control supply voltage Us at AC 60 Hz 220 ... 230V, type of voltage for actuation AC, rated operational power at AC-3, 230 V , 3-phase 1.1kW, rated operational power at AC-3, 400 V 2.2kW, rated operational current Ie 6.3A, rated operational current at AC-3, 400 V 6.3A, overload release current setting 4 ... 6.3A, number of Auxiliary contacts as NO contacts 0, number of auxiliary contacts as NC contacts 0, ambient temperature, upper limit without restrictions 40°C, temperature-compensated overload protection, tripping class CLASS 10, connection type main circuit screw connection, design of electrical connection for auxiliary and control circuit screw connection, number of command points 2, suitable for EMERGENCY -OFF, type of coordination according to IEC 60947-4-3 class 1, number of indicator lights 0, degree of protection (IP) IP55, width 175mm, height 165mm, depth 177mm, direct connection lasser with magnetic release up to 15 kWThe combination of TeSys GV2 motor-protective circuit-breaker and TeSys D contactor for maximum reliability, compact designs and the simplest selection.
... more
Type of motor starter Direct starter (DOL)
With short-circuit release yes
Voltage type for actuation AC
Rated operating power at AC-3, 400V 2.2 kW
Rated power, 460 V, 60 Hz, 3-phase 3 kW
Rated operational current Ie 6A
Rated operating current at AC-3, 400 V 6A
Overload release Current setting 4..6.3 A
Temperature compensated overload protection yes
Trip class CLASS 10
Connection type main circuit Screw
Rail mounting possible no
With transformer no
Number of command points 4
Suitable for EMERGENCY STOP yes
Assignment type according to IEC 60947-4-3 Class 1
External reset possible no
With fuse no
IP protection) IP55
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Width 175 mm
Height 165 mm
Depth 177 mm