Power contactor LC1D 3p 1NO+1NC,37kW,80A,400V - Magnet contactor 66A 110VAC LC1D80AF7

Schneider Electric - LC1D80AF7 - Power contactor LC1D 3p 1NO+1NC,37kW,80A,400V - Magnet contactor 66A 110VAC LC1D80AF7
Photo source: fig. possibly similar
LC1D80AF7 3606481312136 EAN/GTIN DE 33842582 WEEE

£204.58 incl. VAT (£0.00)
£363.04 (-43.65% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Magnet contactor 66A 110VAC, Magnet contactor 66A 110VAC Rated control supply voltage Us at AC... more
Power contactor LC1D 3p 1NO+1NC,37kW,80A,400V - Magnet contactor 66A 110VAC LC1D80AF7 – Schneider Electric – 3606481312136: Magnet contactor 66A 110VAC, Magnet contactor 66A 110VAC Rated control supply voltage Us at AC 50HZ 110 ... 110V, Rated control supply voltage Us at AC 60HZ 110 ... 110V, Voltage type for actuating AC, Rated operation current Ie at AC-1, 400 V 80A, Rated operation current Ie at AC-3, 400 V 66A, Rated operation power at AC-3, 400 V 37kW, Rated operation current Ie at AC-4, 400 V 65A, Rated operation power at AC-4, 400 V 30kW, Rated operation power NEMA 29,8kW, Suitable for DIN installation panels, Number of auxiliary contacts as normally open contact 1, Number of auxiliary contacts as normally closed contact 1, Type of electrical connection of main circuit Screw connection, Number of normally closed contacts as main contact 0, Number of main contacts as normally open contact 3
... more
Voltage type for actuation AC
Rated operational current Ie at AC-1, 400V 80 A
Rated operational current Ie at AC-3, 400 V 66 A
Rated operating power at AC-3, 400V 37 kW
Rated operational current Ie at AC-4, 400V 65 A
Rated operational power at AC-4, 400 V 30 kW
Rated operating power NEMA 29,8 kW
Suitable for serial installation yes
Number of auxiliary contacts as normally open 1
Number of auxiliary contacts as NC contact 1
Connection type main circuit Screw
Number of make contacts as main contacts 3