Transformer circuit breaker 23.0A - Motor protection circuit-breaker 23A GV2RT21

Schneider Electric - GV2RT21 - Transformer circuit breaker 23.0A - Motor protection circuit-breaker 23A GV2RT21
Photo source: fig. possibly similar
GV2RT21 3389110520729 EAN/GTIN DE 33842582 WEEE

Our best price
£64.36 incl. VAT (£0.00)
£110.39 (-41.7% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Transformer circuit breaker 23.0A GV2RT21 overload release current setting 17 ... 23A, setting... more
Transformer circuit breaker 23.0A - Motor protection circuit-breaker 23A GV2RT21 – Schneider Electric – 3389110520729: Transformer circuit breaker 23.0A GV2RT21 overload release current setting 17 ... 23A, setting range of the instantaneous short-circuit release 400 ... 400A, with thermal protection, sensitive to phase failure, thermomagnetic release technology, rated operating voltage 0 ... 690V, rated continuous current Iu 23A, rated operating power at AC-3, 230 V 5.5kW, rated operational power at AC-3, 400 V 9kW, connection type main circuit screw connection, design of the actuating element rocker arm, device design complete device in the housing, number of poles 3, rated limiting short-circuit breaking current Icu at 400 V, AC 15kA, protection class (IP) IP20, height 89mm, Width 45mm, depth 78.5mm, motor protection switch with thermal and magnetic tripping These devices are easy to use and set up, with compact and ergonomic products for starter motor and stop motor requirements.
... more
Overload release Current setting 17..23 A
With thermal protection yes
Phase failure sensitive yes
Release system thermomagnetic
Rated operating voltage 690V
Rated continuous current Iu 23A
Rated operating power at AC-3, 230V 5.5 kW
Rated operating power at AC-3, 400V 11 kW
Connection type main circuit Screw
Execution of the actuating element Rocker arm
Device construction Complete device in the housing
With integrated auxiliary switch no
With integrated undervoltage release no
Number of poles 3
IP protection) IP20
Height 89 mm
Width 45 mm
Depth 78.5 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Transformer circuit breaker 23.0A - Motor protection circuit-breaker 23A GV2RT21"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.