RCD 4P 40A 30mA - Residual current breaker 4-p A9Z61440

A9Z61440 3606489502706 EAN/GTIN DE 33842582 WEEE

Our best price
£245.50 incl. VAT (£0.00)
£926.90 (-73.51% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI switch 4P 40A 30mA A9Z61440 number of poles 4, rated voltage 400V, rated current 40A, rated... more
RCD 4P 40A 30mA - Residual current breaker 4-p A9Z61440 – Schneider Electric – 3606489502706: FI switch 4P 40A 30mA A9Z61440 number of poles 4, rated voltage 400V, rated current 40A, rated residual current 30mA, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 6kV, mounting type DIN rail, residual current type B, short-circuit strength (Icw) 10kA, surge current strength 3kA, frequency 50 Hz, Additional equipment possible, with locking device, degree of protection (IP) IP20, width in modular widths 4, installation depth 44mm, ambient temperature during operation -25 ... 60°C, degree of pollution 3, connectable conductor cross-section stranded 1 ... 25mm², connectable conductor cross-section solid 1 . .. 35mm², residual current circuit breaker universal current sensitive Acti 9 iID. 4-pole, rated current 40A, type B-SI, rated residual current 30mA, operating voltage (Ue) 400 AC, 50Hz, insulation voltage 500V AC. Snap action for low-wear switching of the contacts. With mechanical error message display on the front (VisiTrip) for displaying trips due to residual current. Safe contact indicator (VisiSafe) of the residual current circuit breaker, green indicator means there is no voltage on the outgoing side. Test button for regular function testing. Double connection terminals for connecting cables or busbars on both sides. Simple removal of the individual device with the phase busbar installed, thanks to the fastening element that can be reached from the front. Additional add-on auxiliary modules (optional) undervoltage release (iMN), overvoltage release (iMSU), shunt release (iMX), auxiliary switch for status reporting (iOF), fault signaling switch (iSD). Type B-SI integrates SI technology, which offers higher immunity to electrical interference. Protects against smooth DC residual currents in 1- or 3-phase supply networks caused by frequency converters, inverters and emergency power supplies. Color RAL 9003. Complies with the following standards IEC/EN 61008-2-1,IEC/EN 62423,IEC 61543,VDE 0664.
... more
Number of poles 4
Rated voltage 400V
Rated current 40 A
Rated fault current 0.03 A
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 6 kV
Mounting DIN rail
Fault current type B
Selective type no
Short time delayed type no
Short-circuit strength (Icw) 10 kA
Surge current resistance 3 kA
Voltage AC
With locking device no
Frequency 50 Hz
Additional equipment possible yes
IP protection) IP20
Width in division units 4
Depth 44 mm
Pollution degree 3
Explosion protection no