Residual current block 4p 63A 300mA - Residual current circuit breaker module 19016

Schneider Electric - 19016 - Residual current block 4p 63A 300mA - Residual current circuit breaker module 19016
Photo source: fig. possibly similar
19016 3303430190165 EAN/GTIN DE 33842582 WEEE

£227.25 incl. VAT (£0.00)
£474.62 (-52.12% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Residual current block 4p 63A 300mA 19016 rated voltage 230 ... 415V, rated current 63A, rated... more
Residual current block 4p 63A 300mA - Residual current circuit breaker module 19016 – Schneider Electric – 3303430190165: Residual current block 4p 63A 300mA 19016 rated voltage 230 ... 415V, rated current 63A, rated fault current 0.3 ... 0.3A, max. delay time 0ms, number of poles 4, fault current type A, surge current strength 3kA, frequency 50/60 Hz, rated insulation voltage Ui 690V, Rated impulse withstand voltage Uimp 8kV, Connectable conductor cross-section, solid 1.5 ... 50mm², Connectable conductor cross-section, stranded 1 ... 35mm², With locking device, Degree of protection (IP) IP20, Degree of pollution 3, Ambient temperature during operation 25 ... 60°C, RCD Block Acti 9 Vigi NG125. 4-pole, rated current 63A, rated residual current 300mA, type A, operating voltage (Ue) 400-415V AC, insulation voltage (Ui) 690V AC. Can be mounted on the right side of the NG125 series miniature circuit breakers. Tripping due to residual current is indicated by a red, mechanical indicator on the toggle. Terminals IP 20. Test button for regular function testing. Technology of trip unit - thermomagnetic. Additional add-on auxiliary modules (optional) - shunt release (MXV) and fault signaling switch (SDV). The Vigi NG125 RCD complies with the following standards - IEC/EN 61009-1. Furthermore, this series is VDE certified!
... more
Nominal voltage 230..415 V
Current 63 A
Rated fault current adjustable no
Rated fault current 0.3 A
Max. Delay time 0ms
Delay time adjustable no
Number of poles 4
Fault current type A
Surge current resistance 3 kA
Frequency 50/60 Hz
Rated insulation voltage Ui 690V
Rated impulse withstand voltage Uimp 8 kV
False triggering protection no
With locking device yes
IP protection) IP20
Pollution degree 3