The following 7498 products have been found matching your search "Combi":

Item/s (7498)

Categories | Others (10)

Found in manufacturer pages: 1

ITW Spit - In this catalog from the eibabo® technology store you will find the products of the international corporation 'Illinois Tool Works (ITW)'. The company is represented in Germany by ITW Befestigungssysteme GmbH from Hemmingen in Lower Saxony. The main business area includes the manufacture and sale of products related to the construction industry. This includes fasteners and components as well as devices and consumables. The product groups are divided into nail, staple and bolt setting technology for wood, concrete and steel, drilling and chiselling technology, diamond technology and vacuum cleaners, cordless tools, Toolmatic automation technology, chemical and mechanical dowels, fence products and screws. The products from the field of nail and staple technology are sold under the brand names Paslode, Duo-Fast or Haubold and are used in trade, in manufacturing and in many areas of heavy industry. The Spit brand is characterized by diamond, drilling and chiseling technology as well as fastening technology and bolt-firing tools. From this extensive portfolio, you can get milling heads, wet and dry vacuum cleaners, slot cutters, diamond cutting discs, battery chargers, clamps, combi hammer drills, drill bits, nailing devices and nail magazines, drill bits, chisels, perforated tape and much more. Our customers in the structural and dry construction sectors in particular like to use high-quality, precise and robust ITW technology. The founding of the parent company took place in 1912. It was initiated by Byron L. Smith as a financier who, with four other investors, sought to build a progressive company manufacturing and selling metal cutting tools. Today, the ITW Group has over 800 subsidiaries and more than 50,000 employees worldwide.

Found in shop categories: 9

Combi i/o device - Combi IO devices are essential components of complex building automation. Find out here how to use the high-quality IO devices and what options there are for your installation. In any case, these devices increase the efficiency of your installation. Learn more about these modules and why it is so important for them to work properly.What is an IO device?An IO device - also known as an input-output module - enables communication between a computer system and a peripheral device. This type of processor communication between devices increases a computer's capabilities. The operating system is enabled to connect to the outside world. Communication and interaction takes place through sending and receiving information. Possible input information are, for example, signals from user inputs or binary inputs. Output signals are sent by the system or converted into actions as manipulated variables by actuators. With the use of a multifunctional input module, the work can be carried out more efficiently and accurately. Typical IO devices include:KNX universal interfacesKNX universal controllerKNX switching actuators with integrated binary inputsKNX button interfaces with outputs for LED controlspecial KNX room controller with a variety of special functions  TIP:An IO device can interface with a large number of bus protocols, for example PC Cards, USB, PCI, VMEbus and FireWire. In this eibabo® category you will find, for example, KNX devices with multiple functions from top manufacturers such as ABB, Berker, Busch-Jaeger, Gira, Hager, Issendorf, Jung, Lingg & Janke, MDT, Merten, Siemens and Theben.What are the most important functions of an IO device?An IO device is an essential link in the control chain and closes the gap between your computer system and the external devices. It can perform multiple functions including:Communication between the devices in the systemAn IO device assumes several functions within the scope of device communication. This includes the transmission of status messages, the sending of commands and the transmission of information.communication to the processorFull communication with the processor includes recognizing its own IP address, decoding and accepting commands, and reporting status updates.error managementAn IO device detects different types of problems that can occur between the computer system and a peripheral device. These can be mechanical problems, such as a used printer cartridge or errors that occur during data transfer.Image: ABB IO actuator 8-fold IO/S8.6.1.1timingIn order to be able to correctly manage the flow of information between the system and the external device as part of time management, the IO device accesses the internal resources of a computer.data bufferingOne of the most important functions of an IO device is managing the transmission speed between memory, processor and other external devices.How and where can IO devices be mounted?There are many options for mounting IO devices and they depend on your existing installation. Choose from the following options:Panel mounting - the unit is bolted to a chassis or attached to a panelRack mounting - the device fits into a standard housing, such as a 19-inch rack or similarInstallation on DIN rails - the device is attached to one of the common DIN rails or G-railsfree installation - the device has a stable housing and is set up in a freely selectable placePrinted circuit board assembly - the device plugs directly into computers or is attached to the case What advantages do IO devices offer?Depending on the IO device involved, each can play a significant role within an effective operating system. In a programmable logic controller (PLC) and other operating systems, these devices offer the following advantages:a compact design saves space in almost any assembly environmentthe installation can be done remotelyHardware and associated costs can be savedthe wiring and cable setup is simple and clear What are the properties of the inputs and outputs on the IO devices?As a rule, IO devices offer digital channels, analog channels or a combination of both variants. The digital inputs and outputs handle low-level on-off signals. Analog inputs recognize signals such as current, voltage or frequency. Devices with combined channels often process the signals using analog-to-digital converters.The input channels of a device are differentiated as single-ended (SE) or differential (DI). Single-ended inputs consist of two contacts, one of which carries a voltage. The other is connected to ground. Such installation is simpler and cheaper than differential signaling. However, the inductance of the signal line and the difference in ground voltage between the transmitter and receiver will cause noise interference. Differential communication uses two mutual signals on two paired contacts. The difference between the two signals represents the meaningful signal value. Common-mode rejection prevents noise interference. Differential inputs respond to the voltage difference between the two contacts. These are therefore suitable for low-voltage, long-distance and high-resolution applications. The type of input channels your device has can usually be found in the product description. For example, if you have a 16SE-8DI device, it offers 16 single-ended and 8 differential inputs.isolationCertain areas of the electrical system can be isolated from others. This avoids unwanted current flow or signal flow between the areas.For isolation, please distinguish between channel-to-channel isolation, isolated analog input, isolated analog output, isolated digital input, and isolated digital output.  Catalogue content:In this eibabo® catalogue Installation bus systems > I/O device for bus system you will find items from the following product groups:Item overview:Blind controlCentralAccessControl deviceControl elementControl panelControl unitDrive elementDriver moduleEngine control unitHeating actuatorHome serverInput moduleInterfaceJunction boxLight actuatorMixing moduleMulti-controllerOutdoor areaRadio systemSecurity adapterShutter actuatorSmartphoneSun protection actuatorSwitching actuatorSwitching outputUniversal interfaceWireless solutionWireless switching outputfrom the following manufacturers:Manufacturer overview catalogue Combi i/o device:ABBBusch JaegerGiraHagerLingg & JankeMetzSiedleSomfyWaremaWindowMaster
Combi earth leakage circuit breaker - How do you protect yourself from fires in electrical installations? Which devices prevent fires? How do you find the right fire protection switch and what specification should you pay attention to? This eibabo® catalog contains combination RCCBs/line protection with a focus on fire protection. Did you know that about a third of the fires in Germany inside buildings have an electrical origin? Three quarters of this can be traced back to electrical devices or the electrical installation. How can you face this danger? Electricity is omnipresent and it is impossible to imagine our everyday lives without it. As a rule, the classic measures for protection against overload, short circuits and residual currents are considered sufficient and comprehensive fire protection is therefore also assumed. But this protection is not unlimited. In this article, we will bring you closer to the function of suitable fire protection switches and arc fault circuit breakers.Image: ABB DS ARC1 C20 A30 fire protection switchWhat is a combination RCD/line protection with fire protection function?If switches for fault currents and line protection are combined, this results in FI/LS combination switches. These protective switching devices combine the functionalities of residual current circuit breakers and miniature circuit breakers. What are these properties? A residual current circuit breaker prevents you from getting a dangerous electric shock if you touch something that is live. This switch provides personal protection that ordinary fuses and a circuit breaker cannot provide. A circuit breaker is an electromechanical device used to protect a circuit from excess current caused by either an overload or short circuit. So while a residual current circuit breaker only protects people from electric shocks caused by ground faults and a miniature circuit breaker is only used to protect against overcurrent, the combination of both switches offers comprehensive protection against both types of faults.Good to knowAn arc fault switch is an arc flash detection device. Its purpose is to detect the presence of dangerous electrical arcs and to isolate the affected circuit.Added to this protection is another safety feature - arc flash detection. Devices with this capability are referred to as fire circuit breakers, arc fault circuit breakers, or AFDD. The abbreviation AFDD stands for the English term 'Arc Fault Detection Device'.Why do I need a fire protection switch?Fusing with an RCBO combination switch already protects against many dangers. But there is a kind of error that the classic RCBO combination switch does not recognize. These are arcs within a cable or connection. But what is an arc? An electrical arc occurs when electrical current crosses a physical separation between two conductive materials. If only little current flows, a short-term spark is produced. If the current is high enough, a continuous arc is generated. This can result in temperatures of over 6000°C and gaseous air turns into plasma. In principle, arcs are not a problem as long as they are generated in a controlled manner, for example in an electric motor or in a light switch. However, when accidental arcing occurs in a circuit, a fire can occur due to the intense heat from combustible materials. Common causes are:Damaged insulation of current-carrying conductorsFaulty cable connections and line connections These causes are often caused by improper handling. These include:kinking, crushing and twisting of cables and linesdamage caused by screws, nails or drillsloose connections between two cable endsPoor cable protection and mounting (damage from mechanical stress, movement or rodents) To minimize the risk of fire from these faults, fire protection switches have arc fault protection devices and offer protection against serial and parallel arc faults. A serial arcing fault occurs between two parts of the same phase of a line. A parallel arcing fault occurs when the arc occurs between the phase conductor and either the neutral conductor or the earth conductor.How does the arc fault protection device work on a fire protection switch?Fire protection switches continuously monitor the waveform of the electrical current flowing through one or more circuits. Arcs affect this current flow. If the device detects an unusual signature in the wave, the circuit is broken. 'Normal' arcs that occur during the operation of electrical systems (e.g. in the electric motor) are recognized by the device as harmless. With these, the protective mechanism does not trigger. But beware! A fire protection switch does not recognize:Phase-to-earth fault such as a residual current circuit breakerLine-to-neutral fault like a circuit breakerOverload like a circuit breaker For this reason, the fire protection switches are usually available in combination with RCBOs or are combined with them in the control cabinet.When should I buy a combination RCD/line protection with fire protection function?Basically, we always recommend not to save on your own safety. Even if a fire protection switch is not necessary to protect all circuits, the damage in the event of a fire is usually higher than the additional costs for such a device. Of course, you have to weigh the risk yourself. In certain facilities and parts of the building, however, the use of a fire protection switch always makes sense. This can be:Institutions with valuable goods (jewelers or museums)Rooms with combustible contents (barns, laboratories)oxidizing structures (chimneys, elevator shafts)Buildings open to the public (hotels, retirement homes, youth hostels, hospitals) If you decide against the installation of fire protection switches, please pay attention to the smell of burning from cables or sockets in everyday life. It doesn't have to be an arc fault, but if you smell burnt, you should always look for the cause. Also, if any cord or appliance feels hot to the touch, turn off the affected circuit immediately and, for permanent installations, contact an electrician.for your safetyFire alarms and smoke alarms are additional safety devices that you should never do without in your building. You will find high-quality and reliable devices in our shop. Use our intelligent search.Beware of rapid 'clicking' noises and burn marks on electronic devices. Turn off the affected circuit and have an electrician check the system.What types of fire protection switches are there?As a global electronics retailer, the eibabo® technology store has an extensive range of fire protection switches. Available are:stand-alone devices that you can install in series with a suitable protective device (miniature circuit breaker or residual current circuit breaker).Device combinations that unite the fire protection switch with a combination RCD/line protectionAdditional modules for other protection devices, which are usually only compatible with the protection devices of the respective manufacturer What should I look out for when buying a combination RCD/line protection with fire protection function?The choice of the right switch depends on the tripping characteristics, as is the case with classic RCBOs. There are, among other things, type B and type C combination switches. The main difference lies in the tolerance to the strength of the current surge, which leads to the disconnection of a circuit. TIP:Higher inrush currents can occur when lighting or motors are switched on. Your selected device must be able to distinguish these load peaks from actual errors. Devices with B characteristics are typically used for normal household and non-critical commercial applications. These trigger at residual currents that correspond to three to five times the nominal current. Choose type C devices for commercial and industrial applications. These trip at five to ten times the nominal current.Make sure you choose a reputable manufacturer. With no-name devices, reliable operation cannot be guaranteed and they deviate significantly from the specified values. In our shop you only get the best quality from leading manufacturers such as ABB, Doepke, Eaton and Hager.  Catalogue content:In this eibabo® catalogue Circuit breakers and fuses > Earth leakage circuit breaker with auxiliary device you will find items from the following product groups:Item overview:AFD switchAFDDArc faultArc fault protectionArc fault protection deviceFire protection switchFire protection switching deviceFire switchModular installation devicePersonal protection machinefrom the following manufacturers:Manufacturer overview catalogue Combi earth leakage circuit breaker:ABBDoepkeEatonHager
Grounding bar distributor - The installation and use of electricity has become an integral part of our everyday lives. Each of us is aware that dealing with electricity, especially with high voltage, can sometimes be life-threatening if the necessary protective measures are not observed. So-called grounding plays an important role in this. This refers to the implementation of all necessary measures to divert electrical currents into the ground or into the ground. So that you too can set up your systems safely, we offer you almost everything you need for a modern and efficient electrical installation in our eibabo technology store. In this category you will not only get grounding rails with a different number of terminal points for installation in your fuse box, but also potential equalization bars, busbars, combi brackets, grounding brackets and other distribution terminal blocks to supplement and complete your system.Catalogue content:In this eibabo® catalogue Energy distribution systems > Earthing rail for distribution board you will find items from the following product groups:Item overview:AccessoriesAntenna groundBusbarBusbarsClamping railConnection railControl cabinet grounding barCopper angleEarthing arrangementsEarthing railEarthing rail for distribution boardEMC shield railEquipotential bondingEquipotential bonding railGround angleGround blockGround railGrounding bar for distributorsGrounding materialInterior designNeutral busbarNeutral groundingProtective conductorProtective conductor connectionRailShield railStripStripefrom the following manufacturers:Manufacturer overview catalogue Grounding bar distributor:ABNAstro StrobelEatonFTG GöhringerHagerPollmannRittalSchneider ElectricStriebel & JohnWisiWöhner
CEE socket - All plug connections approved by us are standardized according to CEE. This applies to the flat Euro plug type C, as it is installed on low-voltage light chains, for example, as well as to the well-known German Schuko plug type F. However, the designations of the CEE plug and the CEE socket actually only have two Plug types enforced. These are the red three-phase 400 V three-phase plugs, which are colloquially also not quite correctly called heavy-current plugs, and the blue single-phase 230 V plugs, which are commonly referred to as camping plugs. So if you do woodturning in your free time, often work with a circular saw or are on holiday in a camper van, then you are probably familiar with the CEE socket. If you need CEE plugs and sockets for your installation, you are sure to find the right models here in the eibabo online shop. In addition to variants with different fastening and moisture protection properties, CEE combi sockets are also part of our extensive range.Catalogue content:In this eibabo® catalogue Industrial socket/plug applications > CEE socket outlet you will find items from the following product groups:Item overview:CE standard plug deviceCEE connectorCEE socketCEE socket outletCEE socket outlet, surfaceCEE standard container socketCEE standard wall socketCEE wall socket (AP)CEEform connectorCEEform container socketCEEform extra-low voltage socketCEEform socketCEEform wall boxCekon connectorCekon connectorsCekon container socketExtra-low voltage socketICEE connectorIndustrial plug boxIndustrial socketPlug boxPower socketReceptacleSocketSocket outletThree-phase connectorWall boxWall socketfrom the following manufacturers:Manufacturer overview catalogue CEE socket:ABBABLBachmannBalsBEGA GantenbrinkElektraMennekesPepperl + FuchsPhoenixSchneider ElectricTehalitWalther
Close filters
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
from to

1 From 625
No results were found for the filter!
RECOMMENDED
3D
Dehn - BXT ML4 BD 24 - Blitzductor XT combi arrester module - Combined arrester for signal systems BXT ML4 BD 24
£116.05 incl. VAT (£0.00)

*

plus shipping
(£219.79 RRP***)
Blitzductor XT combi arrester module - Combined arrester for signal systems
Dehn
| BXT ML4 BD 24
RECOMMENDED
3D
ABB - US/U 4.2 - KNX universal interface, push-button interface 4-fold US/U 4.2
£42.16 incl. VAT (£0.00)

*

plus shipping
(£79.39 RRP***)
KNX universal interface, push-button interface 4-fold
ABB
| US/U 4.2
RECOMMENDED
3D
ABB - US/U 2.2 - KNX universal interface 2-fold US/U 2.2
£25.81 incl. VAT (£0.00)

*

plus shipping
(£48.61 RRP***)
KNX universal interface 2-fold
ABB
| US/U 2.2
RECOMMENDED
3D
Gira - 502800 - Switch, blinds actuator 16f/8f 16 A - KNX I/O device for home automation 502800
£242.01 incl. VAT (£0.00)

*

plus shipping
(£437.07 RRP***)
Switch, blinds actuator 16f/8f 16 A - KNX I/O device for home automation
Gira
| 502800
RECOMMENDED
3D
Gira - 503000 - Switch, blinds actuator 24f/12f 16 A - KNX I/O device for home automation 503000
£329.14 incl. VAT (£0.00)

*

plus shipping
(£594.44 RRP***)
Switch, blinds actuator 24f/12f 16 A - KNX I/O device for home automation
Gira
| 503000
RECOMMENDED
3D
Gira - 503800 - Switching, blinds actuator 16f/8f 16 A - KNX I/O device for home automation 503800
£305.08 incl. VAT (£0.00)

*

plus shipping
(£556.66 RRP***)
Switching, blinds actuator 16f/8f 16 A - KNX I/O device for home automation
Gira
| 503800
RECOMMENDED
3D
Gira - 504000 - Switch, blinds actuator 24f/12f 16 A - KNX I/O device for home automation 504000
£375.90 incl. VAT (£0.00)

*

plus shipping
(£685.89 RRP***)
Switch, blinds actuator 24f/12f 16 A - KNX I/O device for home automation
Gira
| 504000
RECOMMENDED
3D
Dehn - DSH B TNC 255 FM - Application-optimised combi drain Type 1+2 TN-C systems - Combined arrester for power systems DSH...
£175.76 incl. VAT (£0.00)

*

plus shipping
(£359.29 RRP***)
Application-optimised combi drain Type 1+2 TN-C systems - Combined arrester for power systems
Dehn
| DSH B TNC 255 FM
RECOMMENDED
3D
Phoenix - SP 2,5/ 1-M - ST COMBI connector - Terminal block connector 1 -p 24A SP 2,5/ 1-M
£0.78 incl. VAT (£0.00)

*

ST COMBI connector - Terminal block connector 1 -p 24A
Phoenix
| SP 2,5/ 1-M
RECOMMENDED
3D
ABB - UK/S 32.2 - KNX universal concentrator, 32-fold UK/S 32.2
£229.08 incl. VAT (£0.00)

*

plus shipping
(£470.08 RRP***)
KNX universal concentrator, 32-fold
ABB
| UK/S 32.2
RECOMMENDED
3D
Dehn - BXT ML2 BE S 24 - Blitzductor XT combi arrester module - Combined arrester for signal systems BXT ML2 BE S 24
£81.24 incl. VAT (£0.00)

*

plus shipping
(£153.87 RRP***)
Blitzductor XT combi arrester module - Combined arrester for signal systems
Dehn
| BXT ML2 BE S 24
RECOMMENDED
3D
Eaton - AFDD-16/2/B/003-A - AFD unit, 2-pole, B16A, 30mA - Earth leakage circuit breaker with AFDD-16/2/B/003-A
£79.90 incl. VAT (£0.00)

*

plus shipping
(£184.64 RRP***)
AFD unit, 2-pole, B16A, 30mA - Earth leakage circuit breaker with
Eaton
| AFDD-16/2/B/003-A
1 From 625