Circuit breaker 3-pole B-16A, 3M QC MBS316

MBS316 3250614314889 EAN/GTIN DE 23692311 WEEE

Our best price
£20.49 incl. VAT (£0.00)
£68.24 (-69.97% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Circuit breaker 3p. B-16A,6kA,3M QC MBS316 tripping characteristic B, number of poles (total) 3,... more
Circuit breaker 3-pole B-16A, 3M QC MBS316 – Hager – 3250614314889: Circuit breaker 3p. B-16A,6kA,3M QC MBS316 tripping characteristic B, number of poles (total) 3, number of fused poles 3, rated current 16A, rated voltage 400V, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, rated switching capacity Icn according to EN 60898 at 400 V 6kA, type of voltage AC , frequency 50 ... 60Hz, energy limitation class 3, suitable for flush-mounted installation, overvoltage category 3, degree of pollution 2, additional equipment possible, width in modular units 3, installation depth 70mm, degree of protection (IP) IP20, ambient temperature during operation -25 ... 70 °C, connectable conductor cross-section stranded 1 ... 25mm², connectable conductor cross-section solid 1 ... 35mm², miniature circuit breaker 3-pole 6kA B-characteristic 16A Quick Connect 3 modules. Miniature circuit breaker with QuickConnect terminal according to E DIN EN 60898-1 (VDE 0641 Part 11), up to 16A at the outlet and up to 63A at the inlet for the busbar system. Contact protection according to IP2x DIN VDE 0106 part 100 with VDE symbol. Circuit breaker with time-delayed thermal release for overload protection and electromagnetic release for short-circuit protection. Suitable for retrofitting additional equipment. Labeling option directly on the device and individual removal from the phase rail network by unlocking the DIN rail quick-release fastener.
... more
Depth 70 mm
Release characteristic B
Number of poles (total) 3
Number of secured poles 3
Rated current 16 A
Rated voltage 400V
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
Voltage AC
Frequency 50..60 Hz
Limiting class 3
Flush mounting yes
Coupling neutral conductor no
Overvoltage category 3
Pollution degree 2
Additional equipment possible yes
Width in division units 3
IP protection) IP20
Explosion protection no

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Circuit breaker 3-pole B-16A, 3M QC MBS316"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.