KNX object controller aluminium - KNX physical sensor 210126

Gira - 210126 - KNX object controller aluminium - KNX physical sensor 210126
Photo source: fig. possibly similar
Photo source: fig. possibly similar
210126 4010337048237 EAN/GTIN DE 59229780 WEEE

Our best price
£87.70 incl. VAT (£0.00)
£137.37 (-36.16% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
EIB object controller alu 210126 bus system KNX, other bus systems without, temperature sensor... more
KNX object controller aluminium - KNX physical sensor 210126 – Gira – 4010337048237: EIB object controller alu 210126 bus system KNX, other bus systems without, temperature sensor version, mounting type flush-mounted, with bus coupling, color aluminum, protection class (IP) IP20, KNX object controller with button interface 4-fold system 55 color aluminum The continuous controller flush-mounted and the object controller combine the functions of a KNX bus coupler , a single room temperature controller with setpoint specification and a binary input. Features: Four potential-free contacts can be connected to the binary input. Input 1 can be used to connect a remote sensor for measuring the temperature in the floor. Two inputs can be parameterized as outputs (max. 0.8 mA). The controller function is used for individual room temperature control. The controller records the current room temperature using an internal or external temperature sensor and processes this into a manipulated variable using an adjustable temperature setpoint. This means that actuators can be controlled with a constant control signal as well as with a switching control signal. Controller: 5 operating modes: comfort, standby, night, frost or heat protection and controller lock (e.g. dew point operation). Heating and cooling functions: heating, cooling, heating and cooling, basic and additional heating, basic and additional cooling. Preset control parameters for common heating or cooling elements. Controller can be switched off (dew point operation) or controller or operation of the controller can be locked. Valve protection function (valve opens cyclically every 24 hours). Control types: Continuous PI control, switching PI control (PWM) and switching 2-point control (on off). Temperature detection via an internal and/or external sensor (averaging for large rooms). Inputs: Free assignment of the functions switching, dimming, blinds and value transmitters to the inputs. Blocking object for blocking individual inputs. Behavior when bus voltage returns can be parameterized separately for each input. Telegram rate limitation. Switching function: two independent switching objects available for each input and can be activated individually, command can be set independently on rising and falling edges (ON, OFF, TOGGLE, no reaction). Dimming function: Single-surface and dual-surface operation, time between dimming and switching and dimming step width adjustable, telegram repetition and stop telegram sending possible. Blind function: command can be set on a rising edge (no function, UP, DOWN, TOGGLE), operating concept can be parameterized (Step - Move - Step or Move - Step), time between short and long-term operation can be set, slat adjustment time can be set. Function of value transmitter and light scene extension: Edge (button as make contact, push button as break contact, switch) and value can be parameterized on edge, value adjustment for button via long key press for value transmitter possible, light scene extension with or without memory function. Temperature sensor function: One channel of the button interface can be used as an external temperature sensor for the room temperature controller. Outputs: Independent switching of a maximum of two outputs. Notes: No separate bus coupler is necessary. When connecting the external inputs, the use of a switch terminal box is recommended. The object controller has no operating or display elements.
... more
Bus system KNX yes
Bus system KNX radio no
Bus system radio bus no
Bus system LON no
Bus system Powernet no
Other bus systems without
Execution Temperature sensor
Mounting Flush
With bus coupling yes
With DCF77 no
Acoustic signal no
With heating no
Colour Aluminum
Analog input no
Weather station no
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "KNX object controller aluminium - KNX physical sensor 210126"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.