Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Valve actuator electromotive 5WG1562-7AB02 bus system KNX, other bus systems without, mounting... more
KNX electromotive actuator 5WG1562-7AB02 – Siemens – 4001869429601: Valve actuator electromotive 5WG1562-7AB02 bus system KNX, other bus systems without, mounting type radiator valve, with bus coupling, temperature and stroke display, number of binary inputs 2, nominal voltage 24V, bus voltage supply, protection class (IP) IP20, the device has separate binary inputs, which can be used as windows or presence contact can be used. The respective value of the associated communication objects can be sent to the bus and e.g. B. can be used to change the operating modes (forced operation frost protection / comfort). By monitoring the time interval between two command value telegrams of the room temperature controller, its function can be monitored. If the telegram fails, an alarm telegram can be triggered and an emergency program activated. In the case of boilers with demand-based flow temperature control, the device can send feedback about the current energy requirement (current max. command value) to the boiler via a group address
... more
Bus system KNX yes
Bus system KNX radio no
Bus system radio bus no
Bus system LON no
Bus system Powernet no
Other bus systems without
Radio bidirectional no
Mounting Radiator valve
With bus coupling yes
Temperature controller with continuous regulation installed no
Keys for manual operation on the drive no
Temperature and stroke display yes
Function master / slave no
Number of digital inputs 2
Nominal voltage 24V
Bus power yes
IP protection) IP20