Circuit breaker ICU=55kA IN=40A 3VA2140-5HL46-0AA0

Siemens - 3VA2140-5HL46-0AA0 - Circuit breaker ICU=55kA IN=40A 3VA2140-5HL46-0AA0
Photo source: fig. possibly similar
Photo source: fig. possibly similar
3VA2140-5HL46-0AA0 4042948832899 EAN/GTIN DE 23691322 WEEE

£469.33 incl. VAT (£0.00)
£818.84 (-42.68% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Circuit-breaker 40A Rated permanent current Iu 40A, Rated short-circuit breaking capacity lcu at... more
Circuit breaker ICU=55kA IN=40A 3VA2140-5HL46-0AA0 – Siemens – 4042948832899: Circuit-breaker 40A Rated permanent current Iu 40A, Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 55kA, Overload release current setting 0,4 ... 1A, Adjustment range undelayed short-circuit release 1,5A, Type of electrical connection of main circuit Frame clamp, Device construction Built-in device fixed built-in technique, Suitable for DIN rail (top hat rail) mounting, Number of auxiliary contacts as normally closed contact 0, Number of auxiliary contacts as normally open contact 0, Number of auxiliary contacts as change-over contact 0, Number of poles 4, Position of connection for main current circuit Front side, Type of control element Rocker lever, Motor drive optional, Degree of protection (IP) IP40
... more
Rated continuous current Iu 40 A
Rated voltage 690V
Overload release Current setting 16..40 A
Integrated earth fault protection no
Connection type main circuit Box terminal
Device construction Built-in device fixed-mounted design
Suitable for DIN rail mounting no
DIN rail mounting optional no
With trip indicator no
With integrated undervoltage release no
Number of poles 4
Execution of the actuating element Rocker arm
Complete unit with protection unit yes
Motor drive integrated no
Motor drive optional yes
IP protection) IP40

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Circuit breaker ICU=55kA IN=40A 3VA2140-5HL46-0AA0"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.