Compact CPU S7-1200 DC/DC/DC - Compact PLC CPU-module PLC-CPU-module 6ES7212-1AE40-0XB0

6ES7212-1AE40-0XB0 4047623402701 EAN/GTIN DE 23691322 WEEE

Our best price
£240.23 incl. VAT (£0.00)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Compact CPU S7-1200 DC/DC/DC 6ES7212-1AE40-0XB0 supply voltage at DC 20.4 ... 28.8V, voltage type... more
Compact CPU S7-1200 DC/DC/DC - Compact PLC CPU-module PLC-CPU-module 6ES7212-1AE40-0XB0 – Siemens – 4047623402701: Compact CPU S7-1200 DC/DC/DC 6ES7212-1AE40-0XB0 supply voltage at DC 20.4 ... 28.8V, voltage type of the supply voltage DC, number of relay outputs 0, max. number of timers 0, compact version, processing time ( 1K, binary instruction) 0.08ms, number of HW interfaces Industrial Ethernet 1, number of interfaces PROFINET 1, number of HW interfaces serial RS-232 0, number of HW interfaces serial RS-422 0, number of HW interfaces serial RS-485 0, number of HW interfaces USB 0, number of HW interfaces parallel 0, number of HW interfaces wireless 0, number of HW interfaces other 0, number of analog outputs 0, number of analog inputs 2, Number of digital inputs 8, number of digital outputs 6, supports protocol for TCP/IP, supports protocol for PROFIBUS, supports protocol for ASI, supports protocol for MODBUS, supports protocol for PROFINET IO, supports protocol for other bus systems e, system component, memory type RAM, memory size 75kByte, DIN rail mounting possible, wall/direct mounting possible, front mounting possible, rack mounting possible, explosion protection category for gas ATEX gas explosion protection, cat. 3G, explosion protection category for dust without, Width 90mm, height 100mm, depth 75mm, SIMATIC S7-1200, CPU 1212C, compact CPU, DC/DC/DC, onboard I/O: 8 DI DC 24V 6 DO 24V DC 2 AI 0-10V DC, power supply: DC 20.4-28.8V DC, program/data memory 75 KB SIMATIC S7-1200 Basic Controller - flexible thanks to a wide range of communication options. The Basic Controllers are the first choice for flexibly and efficiently solving automation tasks in the lower and medium performance range. The central modules are scaled in terms of their performance, are available for different input voltages and with transistor or relay outputs. Safety versions are also available. In addition to the already integrated inputs and outputs, the compact CPUs can be expanded directly on the device or with a wide variety of signal and communication modules in order to adapt them exactly to your requirements. HMI devices can also be connected via the integrated Ethernet interface. The memory of the CPU can be expanded using a memory card, and the PLC is configured with the STEP 7 Basic software in the TIA Portal. The micro PLC has a wide range of networking options via different communication standards through integrated functions (PROFINET, Modbus, etc.) or additional modules (IO-Link, AS-i, etc.) and thus offers maximum flexibility in the structure of the networks and the topology. Due to its compact design, the areas of application for the S7-1200 are very diverse and range from simple packaging machines and heating systems to use as a subordinate system in large plants. Compact design, modular structure and integrated IOs help to save space in the control cabinet. The STEP7 configuration software is integrated into the TIA Portal and thus uses common data management, a uniform operating concept and consistent communication services for all components of a system. This means less project planning effort and faster commissioning.
... more
Supply voltage at DC 20.4..28.8 V
Voltage type of the supply voltage DC
Execution compact
Processing time (1K, binary instruction) 11,6286
Number of HW interfaces Industrial Ethernet 1
Number of interfaces PROFINET 1
Number of analog inputs 2
Number of digital inputs 8th
Number of digital outputs 6
With optical interface no
Supports protocol for TCP / IP yes
Supports protocol for PROFIBUS yes
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI yes
Supports protocol for KNX no
Supports protocol for MODBUS yes
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO yes
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Supports protocol for other bus systems yes
Wireless standard Bluetooth no
Wireless standard WLAN 802.11 no
Radio standard GPRS no
Radio standard GSM no
Radio standard UMTS no
IO-Link master no
System component yes
Redundancy no
With display no
Memory Type R.A.M.
Memory size 75 kbytes
Program memory extension possible no
Rail mounting possible yes
Wall / direct mounting possible yes
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Explosion protection category for dust without
Width 90 mm
Height 100 mm
Depth 75 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Compact CPU S7-1200 DC/DC/DC - Compact PLC CPU-module PLC-CPU-module 6ES7212-1AE40-0XB0"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.