Main switch 1N+1PE 3-pole 63A 22kW - Safety switch 3-p 22kW 3LD2565-0TB51

Siemens - 3LD2565-0TB51 - Main switch 1N+1PE 3-pole 63A 22kW - Safety switch 3-p 22kW 3LD2565-0TB51
Photo source: fig. possibly similar
Photo source: fig. possibly similar
3LD2565-0TB51 4011209524316 EAN/GTIN DE 23691322 WEEE

Our best price
£64.23 incl. VAT (£0.00)
£112.05 (-42.68% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Main switch 1N+1PE 3p. 63A 22kW 3LD2565-0TB51 Design as a main switch Design as a... more
Main switch 1N+1PE 3-pole 63A 22kW - Safety switch 3-p 22kW 3LD2565-0TB51 – Siemens – 4011209524316: Main switch 1N+1PE 3p. 63A 22kW 3LD2565-0TB51 Design as a main switch Design as a maintenance/repair switch Design as a safety switch Number of switches 1 Max. rated operational voltage Ue at AC 690V Rated uninterrupted current Iu 63A Rated uninterrupted current at AC-23 400 V 43A Rated uninterrupted current at AC -21, 400 V 63A, rated operational power at AC-3, 400 V 18.5kW, rated short-time withstand current Icw 1.26kA, rated operational power at AC-23, 400 V 22kW, number of poles 3, number of auxiliary contacts as NC contacts 0, number of auxiliary contacts as NO contacts 0, number of auxiliary contacts as changeover contact 0, device design built-in device, fixed installation technology, suitable for central front mounting, color of the actuating element black, design of the actuating element short rotary handle, lockable, connection type main circuit box terminal, protection class (IP), front IP65, protection class (NEMA) other, SENTRON , 3LD switch disconnector, main switch, 3-pole, Iu: 63 A, operating power / at AC-23 A at 400V: 2 2 kW, insulating-material encapsulation for metric screw connection, rotary drive, black The 3LD main and emergency stop switch for safely switching off loads in a wide variety of environments. The possible uses of the 3LD3 line disconnectors are diverse. After disconnection from the mains, they ensure that all electrical equipment is safely isolated, switching, for example, three-phase motors, but also air conditioning and ventilation systems. 3LD3 are also predestined for the use of control or switching cabinets, especially for applications in small machines (e.g. saws, compressors, pumps, cement mixers, drills, milling machines and woodworking machines). The main features of the Siemens 3LD main and emergency stop switches are: 1. Modular design, quick and easy installation of auxiliary switches, N-PE terminal or 4th pole. 2. Versatile in use thanks to local approvals. 3. One mechanical size for five electrical sizes. 4. Can be used for direct current applications. 5. Types of mounting: front mounting, mounting plate, DIN rail. 6. Optimum mains separation from 16 A to 63 A thanks to the lockable rotary drive. For the safe, efficient electrical infrastructure in buildings and industry, Siemens offers a comprehensive portfolio of protective switching, measuring and monitoring devices, distribution systems, switches and socket outlets.
... more
Version as main switch yes
Version as maintenance / repair switch yes
Version as safety switch yes
Version as emergency stop device no
Version as reversing switch no
Number of switches 1
Max. Rated operating voltage Ue at AC 690V
Rated continuous current Iu 63 A
Rated uninterrupted current at AC-23, 400 V 43 A
Rated continuous current at AC-21, 400 V 63 A
Rated operating power at AC-3, 400V 19 kW
Rated short-time withstand current Icw 1.26 kA
Rated operating power at AC-23, 400V 22 kW
Number of poles 3
Motor drive optional no
Motor drive integrated no
Shunt release optional no
Device construction Built-in device fixed-mounted design
Suitable for ground mounting no
Suitable for front mounting 4-hole no
Suitable for front mounting central yes
Suitable for distributor installation no
Suitable for intermediate construction no
Color of the actuator black
Lockable yes
Connection type main circuit Box terminal
Degree of protection (IP), front side IP65
Protection class (NEMA) other

Rate item