Programmable flush-mounted controller - Room thermostat VT D-UP

VT D-UP 4250939310084 EAN/GTIN DE 84387578 WEEE

Our best price
£154.89 incl. VAT (£0.00)
£187.07 (-17.2% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Programmable flush-mounted controller VT D-UP version on/off, type of power supply 230 V AC,... more
Programmable flush-mounted controller - Room thermostat VT D-UP – Vitramo – 4250939310084: Programmable flush-mounted controller VT D-UP version on/off, type of power supply 230 V AC, three-/four-wire connection, measuring range lower value 5°C, measuring range upper value 30°C, thermal feedback without, control characteristic PI, heating, number of outputs Heating 1, number of cooling outputs 0, differential value 0.5 ... 0.5K, temperature can be read, resistance sensor design, type of installation flush-mounted, with display, operation button, type contact closer, max. voltage of the contacts 230V, max Contact load 10A, protection class (IP) IP30, protection class (NEMA) other, color cream white, RAL number 9010, height 50mm, width 50mm, depth 46mm, temperature controller class I, power consumption in standby mode (solstandby) 0W, digital flush-mounted room thermostat Can be used separately as an independent device or in almost all flat switch systems using intermediate rings in accordance with DIN 49075. With an intermediate frame, which you can obtain from your switch manufacturer, you can easily integrate the room thermostat into an existing light switch system! A standard frame is included in the scope of delivery if you do not want to integrate the room thermostat into an existing switch system. The controller uses an internal sensor to measure the room temperature and closes the heating contact if the temperature falls below the setpoint. The symbol signals the active heating phase. The digital weekly timer has 3 programs for switching between comfort and reduced temperature. The controller is already preset to normal daily routines. Settings are saved permanently. The reset button resets to the factory settings. Temperature setting in 0.5 K increments. Sensor tolerance: ± 0.5 K. Switching difference: approx. 1 K. Power consumption: approx. 1 W. Heating contact: normally open, max. 230 V 8(1)A. Night reduction: normally open contact max. 230 V 10 mA. Internal sensor: NTC 47. Protection class: II after appropriate installation. Ambient temperature: 0...30°C. Storage temperature: -20...+70°C. Radio interference suppression: according to EN 50081-1, EN 50082-1. Power reserve: 4 days after 1 hour of operation. Valve protection: 5 min a/week. with assembly instructions in original packaging. In order to optimally plan the Vitramo heating system, it is not only designed according to DIN EN 12831, but also adapted to the special conditions of the building. Already during the planning phase, a building is divided into rooms, demand zones and heating areas depending on its size and use. A demand zone represents a space/space defined by its specific type of use and conditions such as cooling, ventilation, humidity, etc. Every room needs a room thermostat to regulate the air temperature. Wire-guided room thermostats as room temperature controllers are wired directly to a heating element. Due to the structural conditions, these devices are often used in new buildings or as part of a renovation. If the installed power exceeds the specified switching capacity of the respective room thermostat, then the heating elements must be switched via additional load relays type LS-E. In any case, the life of the room thermostat will be extended if a load relay does the work.
... more
Execution On/Off
Type of power supply 230V AC
Connection three-/four-wire
With receiver no
Measuring range 5..30 °C
External sensor no
Thermal feedback without
control characteristic PI
Suitable for heating yes
Number of outputs Heating 1
Suitable for cooling no
difference value 5K
Difference adjustable no
Temperature readable yes
With noise level indicator no
Version transducer/sensor resistance sensor
Mounting Flush
With display yes
Service Button
Concealed operating element no
With drinking water circuit no
Contact Style Normally open (NO)
Max. Voltage of contacts 230V
Max. Contact load 10 A
IP protection) IP30
Protection class (NEMA) other
Explosion protection no
Colour white
RAL-number 9010
Height 50 mm
Width 50 mm
Depth 46 mm
Temperature controller class I
Compatible with Apple HomeKit no
Compatible with Google Assistant no
Compatible with Amazon Alexa no
IFTTT support available no