Bus Terminal 4AI 4-20mA SE - Fieldbus analogue module 4 In / 0 Out 750-455

750-455 4045454439606 EAN/GTIN DE 40917098 WEEE

Our best price
£203.93 incl. VAT (£0.00)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Bus terminal 4AI 4-20mA SE 750-455, supply voltage at DC=24 V, type of supply voltage=DC, input,... more
Bus Terminal 4AI 4-20mA SE - Fieldbus analogue module 4 In / 0 Out 750-455 – WAGO – 4045454439606: Bus terminal 4AI 4-20mA SE 750-455, supply voltage at DC=24 V, type of supply voltage=DC, input, current=yes, input, voltage=no, input, resistance=no, input, resistance thermometer=no, input, thermocouple =no, input signal configurable=no, resolution of analog inputs=12 bit, output, current=no, output, voltage=no, output signal configurable=no, number of analog inputs=4, analog inputs configurable=no, analog outputs configurable=no , supports protocol for TCP/IP=no, supports protocol for PROFIBUS=no, supports protocol for CAN=no, supports protocol for INTERBUS=no, supports protocol for ASI=no, supports protocol for KNX=no, supports protocol for MODBUS= no, supports protocol for Data-Highway=no, supports protocol for DeviceNet=no, supports protocol for SUCONET=no, supports protocol for LON=no, supports protocol for PROFINET IO=no, supports protocol l for PROFINET CBA=no, supports protocol for SERCOS=no, supports protocol for Foundation Fieldbus=no, supports protocol for EtherNet/IP=no, supports protocol for AS-Interface Safety at Work=no, supports protocol for DeviceNet Safety=no , supports protocol for INTERBUS-Safety=no, supports protocol for PROFIsafe=no, supports protocol for SafetyBUS p=no, supports protocol for other bus systems=no, radio standard Bluetooth=no, radio standard WLAN 802.11=no, radio standard GPRS=no, radio standard GSM=no, radio standard UMTS=no, IO-Link master=no, system component=yes, degree of protection (IP)=IP20, design of the electrical connection=spring-loaded connection, fieldbus connection via separate bus coupler possible=yes, DIN rail mounting possible=yes, wall/ Direct mounting possible=no, Front mounting possible=no, Rack mounting possible=no, Suitable for safety functions=no, Associated equipment (Ex ia)=no, Associated equipment (Ex ib)=n a, Explosion protection category for gas=ATEX gas explosion protection, cat. 3G, Explosion protection category for dust=ATEX dust explosion protection, cat. 3D, width=12 mm, height=64 mm, depth=100 mm , 4-channel analog input 4 ? 20 mA single ended
... more
Supply voltage at DC 24V
Voltage type of the supply voltage DC
Entrance, electricity yes
Input, voltage no
Entrance, resistance no
Entrance, resistance thermometer no
Input, thermocouple no
Input signal configurable no
Resolution of the analog inputs 12 bits
Output, electricity no
Output, voltage no
Output signal configurable no
Number of analog inputs 4
Analog inputs configurable no
Analog outputs configurable no
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Wireless standard Bluetooth no
Wireless standard WLAN 802.11 no
Radio standard GPRS no
Radio standard GSM no
Radio standard UMTS no
IO-Link master no
System component yes
IP protection) IP20
Rail mounting possible yes
Wall / direct mounting possible no
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Width 12 mm
Height 100 mm
Depth 69.8 mm