Surge protection type 2 TN-S 3P+N 20kA - Surge protection for power supply OVRT23N40-275PQ

OVRT23N40-275PQ 2CTB803973R1100 3660308519931 EAN/GTIN DE 91945327 WEEE

Our best price
£86.63 incl. VAT (£0.00)
£290.36 (-70.16% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Overvoltage protection type 2 TN-S 3P+N 20kA OVRT23N40-275PQ Rated discharge surge current (8/20)... more
Surge protection type 2 TN-S 3P+N 20kA - Surge protection for power supply OVRT23N40-275PQ – ABB – 2CTB803973R1100 – 3660308519931: Overvoltage protection type 2 TN-S 3P+N 20kA OVRT23N40-275PQ Rated discharge surge current (8/20) 20kA, rated voltage AC 230V, maximum continuous voltage AC 275V, mounting type DIN rail TH35, size 4 TE, protection level 1.5kV, max. stranded) 25mm², max. conductor cross-section, flexible (finely stranded) 16mm², protection level LN 1.25kV, protection level N-PE 1.4kV, optical signaling on the device, test class type 2, degree of protection (IP) IP20, surge arresters type 2 of the QuickSafe series are suitable to protect electrical low-voltage systems and end devices in the 230/400V system. The devices can be used as surge arresters according to VDE 0100 Part 443 and Part 534 as well as within the framework of the lightning protection zone concept at zone transitions 0B - 1 and higher. The high nominal discharge capacity of 20 kA enables an increased service life compared to the minimum requirements of the standard. The devices consist of a base unit and pluggable protection modules, which can be easily removed to carry out the insulation measurement. They are fully compatible with the installation devices of the pro M compact series and can be bus-mounted with them via busbars. Automatic circuit breakers from this series can also be used as back-up fuses. The surge arresters are tested as type 2 arresters according to the test standard DIN EN 61643-11 (VDE 0675 part 6-11) and class II according to IEC 61643-11.
... more
Network form DC no
Network form IT no
Network shape TN yes
Mains form TN-C no
Mains form TN-CS yes
Mains form TN-S yes
Network shape TT yes
Network form other no
Number of conductors (without earth) 4
Nominal discharge current (8/20) 20 kA
Max. Surge current (8/20) 20 kA
Rated voltage AC 230V
Highest continuous voltage AC 275 V
Highest continuous voltage DC 350V
Protection level 1.5 kV
Protection level LN 1.25 kV
Protection level N-PE 1.4 kV
Short-circuit resistance (Isccr) 100 kA
Integrated short-circuit protection no
Integrated backup fuse no
Free from leakage current yes
Mounting other
Size 4 TE
With telecommunication contact no
Signaling on the device optical
Test class type 2 yes
IP protection) IP20