Combined arrester for power systems DSH ZP B2 SG TNS 255

DSH ZP B2 SG TNS 255 909440 4013364409866 EAN/GTIN DE 11890845 WEEE

Our best price
£225.63 incl. VAT (£0.00)
£474.47 (-52.45% RRP***)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Combined arrester TN-S DSH ZP B2 SG TNS 255, network type DC = no, network type TN-C = no,... more
Combined arrester for power systems DSH ZP B2 SG TNS 255 – Dehn – 909440 – 4013364409866: Combined arrester TN-S DSH ZP B2 SG TNS 255, network type DC = no, network type TN-C = no, network type TN-S = yes, network type TT = no, number of poles = 4, lightning impulse current (10/350 µs) = 30 kA, highest continuous voltage AC = 255 V, nominal voltage AC = 230 V, protection level L-PE = 1.5 kV, protection level N-PE = 1.5 kV, follow current extinguishing capacity = 25 kA, mounting type = busbar, signaling on device = optical, Test class = type 1 and 2, blowing out = no, energy-coordinated protective effect to the end device = yes, protection type (IP) = IP30, combination arrester protective effect type 1 + type 2 for TN-S systems (4 + 0 switching) incl. Overcurrent-protected 230 V power supply (N and L) each for RfZ / APZ acc. VDE-AR-N 4100, can be assembled completely without tools thanks to Click + Power connection technology for the 40 mm busbar system and push-in grounding clamp. For use in the main power supply system according to DIN VDE 0100-443 in buildings (also with overhead line feed, without external lightning protection system). A suitable cover clip according to DIN VDE 0603-1 for every standard meter field, plus 2 x socket and 2 x plug (without connecting cables) for wiring the intelligent measuring system according to VDE-AR 4100 is included in the scope of delivery.
... more
Network form DC no
Network form IT no
Network shape TN no
Mains form TN-C no
Mains form TN-CS no
Mains form TN-S yes
Network shape TT no
Network form other no
Number of poles 4
Lightning impulse current (10/350 µs) 30 kA
Highest continuous voltage AC 255V
Rated voltage AC 230V
Protection level L-PE 1.5 kV
Protection level N-PE 1.5 kV
Follow current extinguishing capability 25 kA
Specific energy (W / R) 20..58 °
Mounting Bus bar
Remote signaling no
Signaling on the device optical
Test class Type 1 and 2 and 3
Integrated backup fuse no
Voltage switching spark gap technology yes
Overcurrent-protected voltage tap-off yes
IP protection) IP30