Power cable - Power cable < 1kV, fix installation NYCY 3x 2,5/2,5Eca

Diverse - NYCY 3x 2,5/2,5Eca - Power cable - Power cable < 1kV, fix installation NYCY 3x 2,5/2,5Eca
Photo source: fig. possibly similar
Photo source: fig. possibly similar
NYCY 3x 2,5/2,5Eca NYCY 3x 2,5RE/ 2,5 Eca S

Our best price
£2.22 incl. VAT (£0.00)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
NYCY 3x 2.5RE/ 2.5 Eca S power cable NYCY 3x 2.5/2.5Eca conductor material copper, conductor... more
Power cable - Power cable < 1kV, fix installation NYCY 3x 2,5/2,5Eca – Diverse – NYCY 3x 2,5RE/ 2,5 Eca S: NYCY 3x 2.5RE/ 2.5 Eca S power cable NYCY 3x 2.5/2.5Eca conductor material copper, conductor nominal cross-section 2.5mm², conductor class class 1 = solid, conductor shape round, number of cores 3, core insulation material polyvinyl chloride (PVC), core identification color, concentric conductor copper, concentric conductor nominal cross-section 2.5 mm², sheath material polyvinyl chloride (PVC), sheath color black, fire behavior class according to EN 13501-6 Eca, insulation integrity no, functional integrity no, outer diameter approx. 14.5mm, min. permissible bending radius, stationary use/permanently installed 218mm, permissible max. conductor temperature 70°C, perm. Outside cable temperature during assembly/handling -5 ... 50°C, perm. External cable temperature after installation without vibration -30 ... 70°C, rated voltage U0 0.6kV, rated voltage U 1kV, energy cables for industry and switchgear, power stations, house connections and street lighting as well as control cables for the transmission of control and regulation pulses and measured values. Where increased electrical and mechanical protection is required. Laying outdoors, in the ground, in water, indoors and cable ducts. The concentric conductor (C) may be used as a middle ground or neutral conductor. At the same time, it may serve as a screen, eg as grounded protection against accidental contact. Copper base: hollow prices
... more
Conductor material Copper
Conductor cross-section 2.5 mm²
Conductor category Kl.1 = solid
Head shape round
Number of cores 3
Core insulation material Polyvinyl chloride (PVC)
Core identification Color
With protective conductor no
Umbrella no
Drain wire no
Lead sheath no
Concentric conductor Copper
Concentric conductor nominal cross-section 2.5 mm²
Reinforcement no
jacket material Polyvinyl chloride (PVC)
Coat Color black
Fire behavior class according to EN 13501-6 Eca
Low smoke according to EN 61034-2 no
Outer diameter approx. 14.5 mm
Mass 280 kg/km
Permitted max. conductor temperature 70 °C
Rated voltage U0 0.6 kV
Rated voltage U 1 kV