Combination arrester T1T2 - Combined arrester for power systems SPRT12-350/3-AX

Eaton - SPRT12-350/3-AX - Combination arrester T1T2 - Combined arrester for power systems SPRT12-350/3-AX
Photo source: fig. possibly similar
Photo source: fig. possibly similar
SPRT12-350/3-AX 195235 9010238084506 EAN/GTIN DE 92318050 WEEE

£549.91 incl. VAT (£0.00)
£1,148.52 (-52.12% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Combined arrester for power systems, Combined arrester for power systems System configuration TN,... more
Combination arrester T1T2 - Combined arrester for power systems SPRT12-350/3-AX – Eaton – 195235 – 9010238084506: Combined arrester for power systems, Combined arrester for power systems System configuration TN, System configuration TN-C, System configuration TN-C-S, Number of poles 3, Lightning impulse current (10/350 µs) 25kA, Max. continuous voltage AC 350V, Max. continuous voltage DC 0V, Nominal voltage AC 240V, Nominal voltage DC 0V, Max. PV-voltage 0V, Voltage protection level 1,5kV, Voltage protection level L-N 1,5kV, Voltage protection level L-PE 0kV, Voltage protection level N-PE 0kV, Voltage protection level (DC+ - DC-) 0kV, Voltage protection level (DC+/DC- - PE) 0kV, Follow current extinguishing capability 50kA, Specific energy (W/R) 160kJ/Ohm, Max. conductor cross section solid (solid, stranded) 35mm², Max. conductor cross section flexible (fine-strand) 35mm², Mounting method DIN rail (top hat rail) 35 mm, Construction size 6 modular spacing, Remote signalling, Signalling at the device Optic, Test class Type 1 + 2, Energy-coordinated protection effect with regard to the terminal equipment, Degree of protection (IP) IP20
... more
Network form DC no
Network form IT no
Network shape TN yes
Mains form TN-C yes
Mains form TN-CS yes
Mains form TN-S no
Network shape TT no
Network form other no
Number of poles 3
Lightning impulse current (10/350 µs) 25 kA
Highest continuous voltage AC 350V
Highest continuous voltage DC 0 V
Rated voltage AC 240V
Rated voltage DC 0 V
Max. PV voltage 0 V
Protection level 1.5 kV
Protection level LN 1.5 kV
Protection level L-PE 0 kV
Protection level N-PE 0 kV
Protection level (DC + - DC-) 0 kV
Protection level (DC + / DC- - PE) 0 kV
Follow current extinguishing capability 50 kA
Specific energy (W / R) 160 kJ/Ohm
Mounting DIN rail TH35
Size 6 TE
Remote signaling yes
Signaling on the device optical
Test class Type 1 and 2
Integrated backup fuse no
Voltage switching spark gap technology no
Overcurrent-protected voltage tap-off no
IP protection) IP20