Arc fault protection 1P+N 6kA B-25A 30mA - Earth leakage circuit breaker with ARF925D

Hager - ARF925D - Arc fault protection 1P+N 6kA B-25A 30mA - Earth leakage circuit breaker with ARF925D
Photo source: fig. possibly similar
Photo source: fig. possibly similar
ARF925D 3250611034780 EAN/GTIN DE 23692311 WEEE

Our best price
£165.97 incl. VAT (£0.00)
£288.14 (-42.4% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Arc fault protection 1P+N 6kA B-25A 30mA ARF925D number of poles 2, rated voltage 230V, rated... more
Arc fault protection 1P+N 6kA B-25A 30mA - Earth leakage circuit breaker with ARF925D – Hager – 3250611034780: Arc fault protection 1P+N 6kA B-25A 30mA ARF925D number of poles 2, rated voltage 230V, rated current 25A, rated residual current 0.03A, residual current type A, energy limitation class 3, rated breaking capacity according to EN 61009 6kA, frequency 50Hz, tripping characteristic B, switching neutral conductor, overvoltage category 3, degree of pollution 2, width in modular units 3, installation depth 70mm, additional equipment installed at the factory AFD unit, degree of protection (IP) IP20, arc fault protection device AFDD with FI-LS 1P+N 6kA B-25A 30mA type A 3M. AFDD fire protection switch according to DIN EN 62606 (VDE 0665-10), combined with RCBO 1P+N according to DIN EN 61009-1 (VDE 0664-20), DIN EN 61009-2-1 (VDE 0664-21), with residual current monitoring type A (30 mA), with QuickConnect terminal according to DIN EN 60898-1 (VDE 0641-11). Contact protection according to IP2x DIN VDE 0106 Part 100, one test button each for the AFD unit and for the residual current device. Easy individual removal from the phase busbar assembly. With VDE mark. Suitable for retrofitting additional equipment. Labeling option directly on the device.
... more
Number of poles 2
Rated voltage 230V
Rated current 25 A
Rated fault current 0.03 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 6 kA
Frequency 50 Hz
Release characteristic B
Coupling neutral conductor yes
Overvoltage category 3
Pollution degree 2
Width in division units 3
Depth 70 mm
IP protection) IP2X

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Arc fault protection 1P+N 6kA B-25A 30mA - Earth leakage circuit breaker with ARF925D"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.