Measuring transformer meter 3-phase 1/5A - Transformer kilowatt-hour meter 1A B24 311-10J (1 x S0)

Janitza - B24 311-10J (1 x S0) - Measuring transformer meter 3-phase 1/5A - Transformer kilowatt-hour meter 1A B24 311-10J (1 x S0)
Photo source: fig. possibly similar
Photo source: fig. possibly similar
B24 311-10J (1 x S0) 1401359 DE 66352645 WEEE

£199.51 incl. VAT (£0.00)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Instrument transformer meter 3-phase 1/5A B24 311-10J (1 x S0) Electronic meter type, rated... more
Measuring transformer meter 3-phase 1/5A - Transformer kilowatt-hour meter 1A B24 311-10J (1 x S0) – Janitza – 1401359: Instrument transformer meter 3-phase 1/5A B24 311-10J (1 x S0) Electronic meter type, rated current (In) 1A, maximum current (Imax) 6A, rated voltage (Un) NL 230 ... 230V, rated voltage (Un) LL 400 .. 400V, frequency 50 ... 60Hz, accuracy class B, Polart three-wire/four-wire, measuring transducer version, energy type active and reactive power, suitable for purchase/delivery, calibrated, approval Measuring Instruments Directive, pulse output electrical, pulse type S0, display type digital, mounting type Installation, width in modules 4, design of the interface without, number of positions 7, degree of protection (IP) IP20, type B24 311-10JFor DIN rail mounting 4TE, 2 tariffs2x inputs for controlling the tariffs or for counting external pulses2x outputs optionally as a pulse output for active or reactive energy or as an alarm outputPulse length: 10-990msMeasurement accuracy active energy: class 1Measurement accuracy reactive energy: class 2 (without MID)Connection cross-section measurement: 25mm²Transformer ratio: 1/5AVoltage range: 3x 220-240 AC, -20% -+15%Frequency: 50/60 HzTemperature range: -40 + 70° CelsiusNo resetting of energy meter readingsMeter is calibrated according to MID and approved according to IEC
... more
Counter type electronic
Rated current (in) 1 A
Maximum current (Imax) 6A
Rated voltage (Un) NL 230V
Rated voltage (Un) LL 400V
Frequency 50..60 Hz
Accuracy class B
Polart Three-wire/four-wire
Execution Transducers
Of energy Active and reactive power
Suitable for Purchase / delivery
Calibrated yes
Admission Measuring Instruments Directive
Pulse output electrical
Pulse type S0
Display digital
Mounting Built-in
Width in division units 4
Execution of the interface without
Number of digits 7
IP protection) IP20