Electric air heater alternating current DN 200 - Duct heater, electric 200x281mm 200mm DRH 20-6 R

Maico - DRH 20-6 R - Electric air heater alternating current DN 200 - Duct heater, electric 200x281mm 200mm DRH 20-6 R
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DRH 20-6 R 0082.0144 4012799821441 EAN/GTIN DE 78107228 WEEE

£1,257.04 incl. VAT (£0.00)
£1,919.43 (-34.51% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Electric air heater alternating current DN 200 DRH 20-6 R Housing material steel, protection... more
Electric air heater alternating current DN 200 - Duct heater, electric 200x281mm 200mm DRH 20-6 R – Maico – 0082.0144 – 4012799821441: Electric air heater alternating current DN 200 DRH 20-6 R Housing material steel, protection class (IP) IP43, nominal width duct 200mm, nominal height duct 281mm, nominal diameter duct 200mm, length 375mm, width 200mm, height 281mm, electric air heater for ventilation systems. With integrated temperature controller. With non-glowing tubular heaters made of stainless steel. Room sensor FR 30 P and duct sensor FL 30 P included in delivery. Dirty tubular heaters increase the risk of fire. To prevent this, install air filter TFE. Recommended accessories: air flow monitor LW 9 and air filter TFE... . Safety instructions: There is an increased risk of fire if the tubular heaters are dirty. To prevent this, install air filter TFE. Designed in accordance with VDE, the Equipment and Product Safety Act and the relevant EU guidelines. With 2 independently switching temperature limiters. Minimum distance to combustible materials: 150 mm (if less than this, install suitable insulation). Article: DRH 20-6 R, minimum delivery volume: 170 m3/h, voltage type: three-phase current, rated voltage: 400 V, mains frequency: 50 Hz, IMax: 15 A, protection class: IP 43, mains supply cable: 5 / 1.5 mm2, installation: inside, installation position: horizontal / vertical, housing material: sheet steel, galvanized, weight: 5 kg, nominal width: 200 mm, width: 200 mm, height: 281 mm, depth: 375 mm, air heater type: electric, heating output: 6000 W, suitable for box fans: no, suitable for roof fans: no, suitable for pipe fans: yes, suitable for heat recovery systems: no, suitable for wall-mounted fans: no, suitable for wall-mounted fans: no, suitable for residential building fans: no, suitable for centrifugal fans: no, suitable for circulation fans : no
... more
Material of the housing Steel
IP protection) IP43
Nominal width Channel 200 mm
Nominal height of duct 281 mm
Nominal duct diameter 200 mm
Length 375 mm
Width 200 mm
Height 281 mm