Inline input terminal analog - Fieldbus analogue module 0 In / 0 Out IB IL TEMP 2 RTD-PAC

Phoenix - IB IL TEMP 2 RTD-PAC - Inline input terminal analog - Fieldbus analogue module 0 In / 0 Out IB IL TEMP 2 RTD-PAC
Photo source: fig. possibly similar
Photo source: fig. possibly similar
IB IL TEMP 2 RTD-PAC 2861328 4017918894269 EAN/GTIN DE 50738265 WEEE

£205.62 incl. VAT (£0.00)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Supply voltage AC 50 Hz=0 V, Supply voltage AC 60 Hz=0 V, Supply voltage DC=19,2..30 V, Voltage... more
Inline input terminal analog - Fieldbus analogue module 0 In / 0 Out IB IL TEMP 2 RTD-PAC – Phoenix – 2861328 – 4017918894269: Supply voltage AC 50 Hz=0 V, Supply voltage AC 60 Hz=0 V, Supply voltage DC=19,2..30 V, Voltage type of supply voltage=DC, Input, current=no, Input, voltage=no, Input, resistor=yes, Input, resistance thermometer=yes, Input, thermocouple=no, Input signal, configurable=no, Resolution of the analogue inputs=16 Bit, Output, current=no, Output, voltage=no, Output signal configurable=no, Analogue inputs configurable=no, Analogue outputs configurable=no, Number of HW-interfaces other=2, Supporting protocol for TCP/IP=no, Supporting protocol for PROFIBUS=no, Supporting protocol for CAN=no, Supporting protocol for INTERBUS=no, Supporting protocol for ASI=no, Supporting protocol for KNX=no, Supporting protocol for MODBUS=no, Supporting protocol for Data-Highway=no, Supporting protocol for DeviceNet=no, Supporting protocol for SUCONET=no, Supporting protocol for LON=no, Supporting protocol for PROFINET IO=no, Supporting protocol for PROFINET CBA=no, Supporting protocol for SERCOS=no, Supporting protocol for Foundation Fieldbus=no, Supporting protocol for EtherNet/IP=no, Supporting protocol for AS-Interface Safety at Work=no, Supporting protocol for DeviceNet Safety=no, Supporting protocol for INTERBUS-Safety=no, Supporting protocol for PROFIsafe=no, Supporting protocol for SafetyBUS p=no, Supporting protocol for other bus systems=no, Radio standard Bluetooth=no, Radio standard Wi-Fi 802.11=no, IO link master=no, System accessory=yes, Degree of protection (IP)=IP20, Type of electric connection=Other, Fieldbus connection over separate bus coupler possible=yes, Rail mounting possible=yes, Wall mounting/direct mounting=no, Front built-in possible=no, Rack-assembly possible=no, Suitable for safety functions=no, SIL according to IEC 61508=None, Appendant operation agent (Ex ia)=no, Appendant operation agent (Ex ib)=no, Explosion safety category for gas=None, Explosion safety category for dust=None, Width=12,19999999 mm, Height=138,44 mm, Depth=70,51 mm
... more
Supply voltage at AC 50 Hz 0 V
Supply voltage at AC 60 Hz 0 V
Supply voltage at DC 19.2..30 V
Voltage type of the supply voltage DC
Entrance, electricity no
Input, voltage no
Entrance, resistance yes
Entrance, resistance thermometer yes
Input, thermocouple no
Input signal configurable no
Resolution of the analog inputs 16 bits
Output, electricity no
Output, voltage no
Output signal configurable no
Analog inputs configurable no
Analog outputs configurable no
Number of HW interfaces other 2
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Supports protocol for other bus systems yes
Wireless standard Bluetooth no
Wireless standard WLAN 802.11 no
IO-Link master no
System component yes
IP protection) IP20
Execution of the electrical connection other
Rail mounting possible yes
Wall / direct mounting possible no
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
SIL according to IEC 61508 without
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Explosion protection category for gas without
Explosion protection category for dust without
Width 12.15 mm
Height 2,61242 cm³
Depth 70.51 mm