FI block 2p 25A 30mA type A SI - Residual current circuit breaker module A9W31225

Schneider Electric - A9W31225 - FI block 2p 25A 30mA type A SI - Residual current circuit breaker module A9W31225
Photo source: fig. possibly similar
A9W31225 3606480443664 EAN/GTIN DE 33842582 WEEE

£87.35 incl. VAT (£0.00)
£167.45 (-47.84% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI block 2p 25A 30mA TypA SI A9W31225 rated voltage 230 ... 415V, rated current 25A, rated... more
FI block 2p 25A 30mA type A SI - Residual current circuit breaker module A9W31225 – Schneider Electric – 3606480443664: FI block 2p 25A 30mA TypA SI A9W31225 rated voltage 230 ... 415V, rated current 25A, rated residual current 0.03 ... 0.03A, max Hz, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 6kV, connectable conductor cross-section solid 1 ... 25mm², connectable conductor cross-section stranded 1 ... 16mm², degree of protection (IP) IP20, degree of pollution 3, ambient temperature during operation 25 ... 60°C, RCD -Block Acti 9 Vigi iC60N/H. 2-pole, rated current 25A, rated residual current 30mA, type A, SI, operating voltage (Ue) 400-415V AC, insulation voltage (Ui) 500V AC. Can be mounted on the right side of iC60N/H series miniature circuit breakers. Tripping due to residual current is indicated by a red, mechanical indicator on the toggle. Terminals IP 20. Test button for regular function testing. Technology of trip unit - thermomagnetic. Additional add-on auxiliary modules (optional) - fault signaling switch, auxiliary switch, undervoltage release, overvoltage release, shunt release. The Vigi iC60N/H RCD complies with the following standards - IEC/EN 61009-1. Furthermore, this series is VDE certified!
... more
Nominal voltage 230..415 V
Current 25 A
Rated fault current adjustable no
Rated fault current 0.03 A
Max. Delay time 0ms
Delay time adjustable no
Number of poles 2
Fault current type A
Surge current resistance 3 kA
Frequency 50/60 Hz
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 6 kV
False triggering protection yes
With locking device no
IP protection) IP20
Pollution degree 3