Fieldbus coupler DP/FMS 12 MBD - Fieldbus basic device DC24V 750-303

WAGO - 750-303 - Fieldbus coupler DP/FMS 12 MBD - Fieldbus basic device DC24V 750-303
Photo source: fig. possibly similar
Photo source: fig. possibly similar
750-303 4045454659431 EAN/GTIN DE 40917098 WEEE

Our best price
£359.29 incl. VAT (£0.00)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Fieldbus coupler DP/FMS 12 MBD 750-303 With integrated power supply, input voltage at DC... more
Fieldbus coupler DP/FMS 12 MBD - Fieldbus basic device DC24V 750-303 – WAGO – 4045454659431: Fieldbus coupler DP/FMS 12 MBD 750-303 With integrated power supply, input voltage at DC 24...24V, type of input voltage DC, max. input current at DC 0.5A, number of HW interfaces Industrial Ethernet 0, number of interfaces PROFINET 0 , Number of HW interfaces serial RS-232 0, Number of HW interfaces serial RS-422 0, Number of HW interfaces serial RS-485 1, Number of HW interfaces serial TTY 0, Number of HW interfaces USB 0 , Number of HW interfaces in parallel 0, Number of HW interfaces wireless 0, Number of HW interfaces other 0, Supports protocol for PROFIBUS, System component, degree of protection (IP) IP20, Number of slots 1, With plug-in modules, digital E/ A, with pluggable assemblies, analog I/O, with pluggable assemblies, communication modules, with pluggable assemblies, function and technology modules, with pluggable assemblies, central modules, with pluggable assemblies, other, execution of the electrical Spring-loaded connection, With electrical isolation, With bus coupler for modular station structure, DIN rail mounting possible, Explosion protection category for gas ATEX gas explosion protection, Cat. 3G, Explosion protection category for dust ATEX dust explosion protection, Cat. 3D, width 51mm, Height 65mm, depth 100mm This fieldbus coupler connects the WAGO-I/O-SYSTEM as a slave to the PROFIBUS fieldbus. The bus coupler recognizes all plugged-in I/O terminals and uses them to create a local process image. This can involve a mixed arrangement of analog (data exchange word by word) and digital (data exchange bit by bit) terminals. The image is displayed in the memory of the responsible controller via the PROFIBUS fieldbus. The local process image is divided into an input and an output data area. The process data can be read in via the PROFIBUS and further processed in a controller. The process output data are output via the PROFIBUS. The data from the analog terminals are stored in the automatically created process image in the order of their position after the bus coupler. The bits of the digital terminals are combined into bytes and appended to the analog data. If the number of digital I/Os is greater than 8 bits, the coupler automatically starts another byte. For new installations with PROFIBUS DP, consider the fieldbus coupler 750-333 with extended functions. Caution: Configuration files (GSD) required!
... more
With integrated power supply yes
Input voltage at DC 24V
Type of input voltage DC
Max. Input current at DC 0.5 A
Number of HW interfaces serial RS-485 1
With optical interface no
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS yes
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for SERCOS no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Wireless standard Bluetooth no
Wireless standard WLAN 802.11 no
Radio standard GPRS no
Radio standard GSM no
Radio standard UMTS no
IO-Link master no
System component yes
IP protection) IP20
Number of slots 1
With pluggable assemblies, digital I / O yes
With plug-in modules, analog I / O yes
With plug-in modules, communication modules yes
With pluggable modules, central modules yes
With pluggable modules, miscellaneous yes
With electrical isolation yes
With bus coupler for modular station design yes
Rail mounting possible yes
Wall / direct mounting possible no
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Width 50.5 mm
Height 100 mm
Depth 71.1 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Fieldbus coupler DP/FMS 12 MBD - Fieldbus basic device DC24V 750-303"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.