Power contactor AC-3/400V:4kW 3p DC - Magnet contactor 9A 0VAC 110VDC DILEM-10-G(110VDC)

Eaton - DILEM-10-G(110VDC) - Power contactor AC-3/400V:4kW 3p DC - Magnet contactor 9A 0VAC 110VDC DILEM-10-G(110VDC)
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DILEM-10-G(110VDC) 010309 4015080103097 EAN/GTIN DE 92318050 WEEE

£34.70 incl. VAT (£0.00)
£54.96 (-36.86% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Rated control supply voltage Us at AC 50HZ=0 V, Rated control supply voltage Us at AC 60HZ=0 V,... more
Power contactor AC-3/400V:4kW 3p DC - Magnet contactor 9A 0VAC 110VDC DILEM-10-G(110VDC) – Eaton – 010309 – 4015080103097: Rated control supply voltage Us at AC 50HZ=0 V, Rated control supply voltage Us at AC 60HZ=0 V, Rated control supply voltage Us at DC=110 V, Voltage type for actuating=DC, Rated operation current Ie at AC-1, 400 V=22 A, Rated operation current Ie at AC-3, 400 V=9 A, Rated operation power at AC-3, 400 V=4 kW, Rated operation current Ie at AC-4, 400 V=6,59999999 A, Rated operation power at AC-4, 400 V=3 kW, Rated operation power NEMA=3,7 kW, Modular version=no, Number of auxiliary contacts as normally open contact=1, Type of electrical connection of main circuit=Screw connection, Number of normally open contacts as main contact=3
... more
Rated control supply voltage Us at DC 110V
Voltage type for actuation DC
Rated operational current Ie at AC-1, 400V 22 A
Rated operational current Ie at AC-3, 400 V 9A
Rated operating power at AC-3, 400V 4 kW
Rated operational power at AC-4, 400 V 3 kW
Rated operating power NEMA 3.7 kW
Suitable for serial installation no
Number of auxiliary contacts as normally open 1
Connection type main circuit Screw
Number of make contacts as main contacts 3