Reversing starter a. Busbar Adapt. - Reversing starter combination 2,2kW MSCR6,3M7230V50HZBBA

Eaton - MSCR6,3M7230V50HZBBA - Reversing starter a. Busbar Adapt. - Reversing starter combination 2,2kW MSCR6,3M7230V50HZBBA
Photo source: fig. possibly similar
Photo source: fig. possibly similar
MSCR6,3M7230V50HZBBA 102988 4015081028276 EAN/GTIN DE 92318050 WEEE

£189.84 incl. VAT (£0.00)
£303.72 (-37.5% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Reversing starter a. Busbar Adapt. MSCR6,3M7230V50HZBBA Type of motor starter reversing starter,... more
Reversing starter a. Busbar Adapt. - Reversing starter combination 2,2kW MSCR6,3M7230V50HZBBA – Eaton – 102988 – 4015081028276: Reversing starter a. Busbar Adapt. MSCR6,3M7230V50HZBBA Type of motor starter reversing starter, with short-circuit release, rated control supply voltage Us at AC 50 Hz 230 ... 230V, rated control supply voltage Us at AC 60 Hz 0V, rated control supply voltage Us at DC 0V, type of voltage for actuation AC, rated operational power at AC-3, 230 V , 3-phase 1.5kW, rated operational power at AC-3, 400 V 2.2kW, rated power, 460 V, 60 Hz, 3-phase 0kW, rated power, 575 V, 60 Hz, 3-phase 0kW, rated operational current Ie 5A, Rated operational current at AC-3, 400 V 6.3A, overload release current setting 4 ... 6.3A, conditional rated short-circuit current, coordination type 1, 480 Y/277 V 0A, conditional rated short-circuit current, coordination type 1, 600 Y/347 V 0A, conditional rated short-circuit current , type of coordination 2, 230 V 50000A, rated conditional short-circuit current, type of coordination 2, 400 V 50000A, number of auxiliary contacts as NO contact 0, number of auxiliary contacts as NC contact 0, ambient temperature, upper limit without Ei Limitations 60°C, temperature-compensated overload protection, tripping class CLASS 10, connection type main circuit screw connection, design of electrical connection for auxiliary and control circuit screw connection, DIN rail mounting possible, number of command points 0, type of coordination according to IEC 60947-4-3 class 2, number of indicator lights 0, Degree of protection (IP) IP20, degree of protection (NEMA) other, width 90mm, height 200mm, depth 154mm, reversing starter, basic device: MSC, Note: Also suitable for motors of efficiency class IE3., IE3-capable devices are marked with the logo on the packaging ., motor data rated operational power AC-3 380 V 400 V 415 V: P= 2.2 kW, setting range overload release: Ir= 4 - 6.3 A, type of coordination: type of coordination ''1'', type of coordination ''2'', actuating voltage: 230 V 50 Hz, 240 V 60 Hz, AC voltage, standards and regulations: IEC/EN 60947-4-1, VDE 0660, UL 508 (on request), CSA C 22.2 no. 14 (on request)
... more
Type of motor starter Reversing starter
With short-circuit release yes
Rated control supply voltage Us at DC 0 V
Voltage type for actuation AC
Rated operating power at AC-3, 400V 2.2 kW
Rated power, 460 V, 60 Hz, 3-phase 0 kW
Rated power, 575 V, 60 Hz, 3-phase 0 kW
Rated operational current Ie 5 A
Rated operating current at AC-3, 400 V 6.3 A
Overload release Current setting 4..6.3 A
Temperature compensated overload protection yes
Trip class CLASS 10 A
Connection type main circuit Screw
Rail mounting possible yes
With transformer no
Suitable for EMERGENCY STOP no
Assignment type according to IEC 60947-4-3 Class 2
External reset possible no
With fuse no
IP protection) IP20
Protection class (NEMA) other
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Width 90 mm
Height 153 mm
Depth 200 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Reversing starter a. Busbar Adapt. - Reversing starter combination 2,2kW MSCR6,3M7230V50HZBBA"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.