Power supply for bus system 80mA DL-N2-80mA

Eltako - DL-N2-80mA - Power supply for bus system 80mA DL-N2-80mA
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DL-N2-80mA 33000026 4010312327685 EAN/GTIN DE 30298319 WEEE

£54.27 incl. VAT (£0.00)
£82.48 (-34.2% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
DALI bus power supply DL-N2-80mA Other bus systems other, flush-mounted mounting type, number of... more
Power supply for bus system 80mA DL-N2-80mA – Eltako – 33000026 – 4010312327685: DALI bus power supply DL-N2-80mA Other bus systems other, flush-mounted mounting type, number of supplyable lines 40, max. output current 80mA, DALI bus power supply with 80mA output current to supply up to 40 standard DALI devices. 59x33x15mm. Suitable for flush-mounted boxes and installation in protection class II devices. The connection terminals are plug-in terminals for conductor cross sections from 0.5mm² to 1.5mm². Input: Supply voltage range 120V..240V AC/50-60Hz. Maximum input current 10mA. Switch-on ramp-up time 250ms. Power loss max. 2W. Output: Output voltage range 12V DC..20.5V DC. Output current 80mA. No-load and short-circuit proof. Protection class housing IP40. Protection class terminals IP20. Impulse voltage category II. Pollution degree 2. Rated insulation voltage 250V. Rated impulse voltage 4kV. Reinforced insulation. Insulation test voltage 3kV. Temperature at the installation site -20°C to +55°C. Storage temperature -20°C to + 75°C. Relative humidity 15% to 90%.
... more
Bus system KNX no
Bus system KNX radio no
Bus system radio bus no
Bus system LON no
Bus system Powernet no
Other bus systems other
Mounting Flush
With LED display no
Bus voltage can be buffered no
Number of available lines 40
Max. Output current 80 mA

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Power supply for bus system 80mA DL-N2-80mA"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.