DALI control with room controller - Interface for bus system LCN - SHD

Issendorff - LCN - SHD - DALI control with room controller - Interface for bus system LCN - SHD
Photo source: fig. possibly similar
LCN - SHD 30307

Our best price
£132.84 incl. VAT (£0.00)

3-5 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
DALI control with room controller LCN - SHD Type of installation Recessed installation, Rated... more
DALI control with room controller - Interface for bus system LCN - SHD – Issendorff – 30307: DALI control with room controller LCN - SHD Type of installation Recessed installation, Rated voltage 230V, Frequency 50 ... 60Hz, Dimming DALI, Type of operation radio, Can be used with button, The LCN-SHD is a control module for DALI operating devices with full LCN functionality: the LCN -SHD controls and regulates climate, light, etc. as a fully-fledged room controller. DALI: 4 light circuits can be controlled with full LCN functionality (compared to DALI more functions). All ballasts on the DALI bus can be controlled directly, since any DALI telegrams can be transmitted via the LCN bus. In this way, DALI direct commands can also be assigned to LCN buttons. In addition, the LCN-SHD has a 0-10V output that can be used, for example, for climate control. For pure 0-10V applications, the DALI output can also be switched to 0-10V, so that two 0-10V outputs are available. Application The LCN-SHD component is used in dry rooms in sub-distribution boards. It occupies 2 TE. The LCN-SHD only supports the initial DALI configuration in single mode. If there are several electronic ballasts on the bus line, please use an appropriate programming device
... more
Mounting Built-in installation
Nominal voltage 230V
Frequency 50..60 Hz
Dimming DALI yes
Of operation Radio
Suitable with button yes