KNX fan coil actuator 2-fold REG housing 4TE - KNX heating actuator FCA 2 REGHE

FCA 2 REGHE 4011377030992 EAN/GTIN DE 64244154 WEEE

Our best price
£186.21 incl. VAT (£0.00)
£299.07 (-37.74% RRP***)

14-16 days* (GBR)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
KNX fan coil actuator 2-fold REG housing 4TE FCA 2 REGHE bus system KNX, mounting type REG, width... more
KNX fan coil actuator 2-fold REG housing 4TE - KNX heating actuator FCA 2 REGHE – Jung – 4011377030992: KNX fan coil actuator 2-fold REG housing 4TE FCA 2 REGHE bus system KNX, mounting type REG, width in modular units 4, with bus coupling, control variable constant, control variable switching, valve protection function, manual switching, max. switching current (resistive load) 10A, number of Outputs 8, max. output current 10A, switching voltage 230 ... 240V, KNX fan coil actuator, 2-fold, REG, with electronic manual control, LED status display and integrated bus coupler ETS product family: heating, air conditioning, ventilation, product type: fan Coil, KNX supply: voltage: DC 21 to 32 V SELV, KNX power consumption: typically 150 mW, mains supply: AC 230/240 V ~, 50/60 Hz, power loss: maximum 3 W, KNX connection: connection and branch terminal, Mains and outputs connection: screw terminals, 0.5 mm² to 4 mm² (solid and finely stranded without ferrule) and 0.5 mm² to 2.5 mm² (finely stranded with ferrule), switch type: make contact, type of contact: potential-free relay contacts, µ-contact, Switching voltage: AC 230/240 V ~, switching capacity n: 10 A (AC-1 and AC-3), switching capacity per load output: resistive load: 2300 W, capacitive load: 10 A (maximum 140 µF), motors: 1380 VA, lamp loads: incandescent lamps: 2300 W, HV halogen lamps : 2300 W, LV halogen lamps 1200 VA (inductive transformer) and 1500 W (electronic transformer) and fluorescent lamps 1000 W (uncompensated), 1160 W (parallel-compensated, 140 µF) and 2300 W (duo circuit, maximum 140 µF), outputs can be operated manually, construction site operation, heating cooling or heating/cooling operation, 2 or 4-pipe operation, individual or hierarchical switching of the fan stages, feedback, output display, blocking function for each channel, operating modes: bus operation: operation via pushbutton sensors or room controller, Short-term manual operation: manual operation on site with keypad, automatic return to bus operation and permanent manual operation: exclusively manual operation on the device, the full functionality is supported from ETS3.0d or higher, ambient temperature: - 5 °C to + 45 °C, storage temperature r: - 25 °C to + 70 °C, width: 72 mm (4 HP), for connecting a fan converter with up to six fan levels or two fan converters, each with up to three fan levels
... more
Bus system KNX yes
Bus system KNX radio no
Bus system radio bus no
Bus system LON no
Bus system Powernet no
Mounting REG
Width in division units 4
With bus coupling yes
Control variable steady yes
Switching manipulated variable yes
Valve protection function yes
Manual gearshift yes
Max. Switching current (resistive load) 10 A
Number of exits 8th
Max. Output current 10 A
Switching voltage 230..240 V